2-23
Confidential
4.5 Troubleshooting for Control Panel Problems
4.5.1 Nothing is displayed on the LCD
4.5.2 Control panel is inoperable
<User Check>
- Turn the power switch OFF and then ON again.
- Check the DC terminal connection.
Step
Cause
Remedy
1
Key attachment failure
Reattach the key.
2
Connection failure of the LCD PCB
flat cable
Reconnect the LCD PCB flat cable.
3
Connection failure of the LCD flat
cable
Reconnect the LCD flat cable.
4
AC cord failure
Replace the AC cord.
5
AC adapter failure
Replace the AC adapter.
6
LCD PCB failure
Replace the LCD PCB ASSY.
7
Main PCB failure
Replace the main PCB ASSY.
<User Check>
- Turn the power switch OFF and then ON again.
Step
Cause
Remedy
1
Key attachment failure
Reattach the key.
2
Connection failure of the LCD PCB
flat cable
Reconnect the LCD PCB flat cable.
3
LCD PCB failure
Replace the LCD PCB ASSY.
4
Main PCB failure
Replace the main PCB ASSY.