II - 18
[
7] Removing the Main PCB Assy and the Mechanical Printing Unit
(1) Unplug the following connectors and cables.
Caution 1: Be sure to unlock the connector before removing the head
flexible cable.
Caution 2: Take care not to damage the connectors and cables.
Fig. 2.2-14 Removing the Connectors and Cables
Half cutter sensor connector (P8)
Sensor PCB harness (P3)
Sub PCB harness (P2)
Head flexible cable (P9)
Connector to
be unlocked
Tape end sensor connector (P4)
Half cutter motor connector (P6)
Main PCB assy
Full cutter motor connector (P5)
Power supply connector (P1)
Body cover
Tape feed motor connector (P10)
Full cutter sensor connector (P7)
Summary of Contents for P-touch PRO DX PT-9200DX
Page 1: ...SERVICE MANUAL MODEL PT 9200DX ...
Page 2: ...SERVICE MANUAL MODEL PT 9200DX ...
Page 5: ...CHAPTER I SPECIFICATIONS ...
Page 11: ...CHAPTER II MECHANISMS ...
Page 66: ...CHAPTER III ELECTRONICS ...
Page 89: ...CHAPTER IV TROUBLESHOOTING ...
Page 92: ...IV 2 2 The tape cassette type is not detected correctly 3 The LED does not light up ...
Page 93: ...IV 3 4 No printing is performed 5 The interface malfunctions ...
Page 94: ...IV 4 6 The tape is not cut ...
Page 95: ...IV 5 7 The tape is not fed correctly ...
Page 96: ...IV 6 ...
Page 97: ...IV 7 8 Half cut is not possible ...
Page 98: ...IV 8 9 The tape is not ejected forcibly ...
Page 99: ...APPENDIX Circuit Diagram Main PCB Power Supply PCB 100 120V Power Supply PCB 230V ...
Page 101: ......
Page 102: ......
Page 103: ......