![Brother MFC-9420CN Service Manual Download Page 96](http://html.mh-extra.com/html/brother/mfc-9420cn/mfc-9420cn_service-manual_54175096.webp)
Confidential
5-7
5.1.4 Fusing
Unit
[ Caution and Request for Replacement of Maintenance Parts ]
(1) The fuser unit is the unit replaceable component and consists of the important
parts that are important for the product safety. The disassembly and replacement
of the maintenance parts shall be performed by the skillful personnel having
completed the appropriate training and at the appropriate location having the
test facilities for the product safety test.
(2) The wiring of the fusing unit is different subject to the voltage specification,
and therefore the wrong installation may cause the H2 error.
(3) When replacing the fusing unit, leave the machine for approx. ten minutes while
the power supply of the machine is ON. Then, turn it off and replace the unit.
[ Description of Applicable Work ]
Replacement of Fuser Lamp, Installation of Heater, and Internal Wiring:
Pin Assignment : 120V - , 240V -
1 .
THS1
THS2
940W
Fuser Connector
Discharge Terminal
Fuser Lamp
Connector Pin No.
To be connected to
the fuser metal frame
(Side Panel)
Insulation Resistance Tester
Thermostat (1)
Thermostat (2)
120V
240V
FG
1
3
4
2
2 3 4
[ Confirmation of Safety ]
Method of
Measurement for
Insulation Resistance:
Connect the insulation
resistance tester as
shown in the figure
above.
Judgment Criteria:
The insulation
resistance to be
100M or greater.
1
2
Caution
1
4
1
3
Summary of Contents for MFC-9420CN
Page 1: ...Confidential FACSIMILE EQUIPMENT SERVICE MANUAL MODELS MFC 9420CN ...
Page 16: ...Confidential CHAPTER 1 PARTS NAMES FUNCTIONS ...
Page 22: ...Confidential CHAPTER 2 SPECIFICATIONS ...
Page 33: ...Confidential CHAPTER 3 THEORY OF OPERATION ...
Page 48: ...Confidential 3 1 4 CBV DBV Fig 3 16 Y M C K Fig 3 17 ...
Page 69: ...Confidential 3 3 5 Fig 3 35 ...
Page 73: ...Confidential 3 3 9 3 Interface Circuit Printer side Fig 3 38 ...
Page 82: ...Confidential CHAPTER 4 TRANSFER OF DATA LEFT IN THE MACHINE TO BE SENT FOR REPAIR ...
Page 85: ...Confidential 4 2 Cover page sample End page sample Fig 4 1 ...
Page 86: ...Confidential CHAPTER 5 DISASSEMBLY REASSEMBLY AND LUBRICATION ...
Page 94: ...Confidential 5 5 5 1 1 AC Cord 1 Disconnect AC cord from the machine Fig 5 1 AC cord Machine ...
Page 175: ...Confidential CHAPTER 6 ADJUSTMENTS AND UPDATING OF SETTINGS REQUIRED AFTER PARTS REPLACEMENT ...
Page 203: ...Confidential CHAPTER 7 CLEANING ...
Page 205: ...Confidential CHAPTER 8 MAINTENANCE MODE ...
Page 213: ...8 6 Confidential Fig 8 2 Scanning Compensation Data List a b c d e f g h i j k l m n q ...
Page 224: ...8 17 Confidential Cover page sample End page sample Fig 8 8 ...
Page 255: ...Confidential CHAPTER 9 ERROR INDICATION AND TROUBLESHOOTING ...
Page 279: ...Confidential 9 23 2 Image failure 1 2 3 4 5 6 7 8 9 10 11 12 13 14 ...
Page 280: ...Confidential 9 24 15 a 15 b 16 17 18 19 20 21 22 23 24 25 Fig 9 1 ...
Page 325: ...App 1 5 Confidential 6 Transfer Unit X X X X X X 7 1 2 3 Location SERIAL NO YEAR MONTH DATE ...
Page 398: ...B Power Supply PCB 100V 127V Confidential ...