![Brother MFC-9420CN Service Manual Download Page 368](http://html.mh-extra.com/html/brother/mfc-9420cn/mfc-9420cn_service-manual_54175368.webp)
App.
4-31
Confidential
WSW27
(Function setting 5)
Selector
No.
Function
Setting and Specifications
1 Not
used.
2
Ringer OFF setting
0: Yes
1: No
3
Automatic playback of OGM when
switched to the TAD mode
0:
No
1:
Yes
4
5
Detection of distinctive ringing
pattern
(Not used.)
0:
Yes
1:
No
6
Recording quality
0:
Normal
1:
High
7
Recording time for high recording
quality
0:
Short
1:
Long
(9.6 kbps)
(8.8 kbps)
8 Not
used.
NOTE:
Selectors 4 and 5 are applicable to the U.S.A. models only.
Selector 2: Ringer OFF setting
This selector determines whether or not the ringer can be set to OFF.
Selector 3: Automatic playback of OGM when switched to the TAD mode
This selector determines whether or not to automatically play back an OGM the moment the
machine switches to the TAD mode.
Selectors 4 and 5: Detection of distinctive ringing pattern (Not used.)
If this selector is set to "1," the machine detects only the number of rings; if it is set to "0," the
machine detects the number of rings and the ringing time length to compare the detected ringing
pattern with the registered distinctive one.
Selector
6: Recording
quality
This selector determines the recording quality for the OGM and ICM. Selecting "1" (High)
increases the quality, sacrificing the recording time.
Selector 7: Recording time for high recording quality
This setting takes effect when selector 6 is set to "1" (High). Setting this selector to "0" (Short)
further increases the recording quality, sacrificing the recording time.
The recording quality and time to be applied when this selector is set to "1" (Long) are higher and
shorter than the ones to be applied when selector 6 is set to "0" (Normal).
The recording quality and time determined by this selector being set to "1" (Long) are higher and
shorter than the ones determined by selector 6 being set to "0" (Normal).
Summary of Contents for MFC-9420CN
Page 1: ...Confidential FACSIMILE EQUIPMENT SERVICE MANUAL MODELS MFC 9420CN ...
Page 16: ...Confidential CHAPTER 1 PARTS NAMES FUNCTIONS ...
Page 22: ...Confidential CHAPTER 2 SPECIFICATIONS ...
Page 33: ...Confidential CHAPTER 3 THEORY OF OPERATION ...
Page 48: ...Confidential 3 1 4 CBV DBV Fig 3 16 Y M C K Fig 3 17 ...
Page 69: ...Confidential 3 3 5 Fig 3 35 ...
Page 73: ...Confidential 3 3 9 3 Interface Circuit Printer side Fig 3 38 ...
Page 82: ...Confidential CHAPTER 4 TRANSFER OF DATA LEFT IN THE MACHINE TO BE SENT FOR REPAIR ...
Page 85: ...Confidential 4 2 Cover page sample End page sample Fig 4 1 ...
Page 86: ...Confidential CHAPTER 5 DISASSEMBLY REASSEMBLY AND LUBRICATION ...
Page 94: ...Confidential 5 5 5 1 1 AC Cord 1 Disconnect AC cord from the machine Fig 5 1 AC cord Machine ...
Page 175: ...Confidential CHAPTER 6 ADJUSTMENTS AND UPDATING OF SETTINGS REQUIRED AFTER PARTS REPLACEMENT ...
Page 203: ...Confidential CHAPTER 7 CLEANING ...
Page 205: ...Confidential CHAPTER 8 MAINTENANCE MODE ...
Page 213: ...8 6 Confidential Fig 8 2 Scanning Compensation Data List a b c d e f g h i j k l m n q ...
Page 224: ...8 17 Confidential Cover page sample End page sample Fig 8 8 ...
Page 255: ...Confidential CHAPTER 9 ERROR INDICATION AND TROUBLESHOOTING ...
Page 279: ...Confidential 9 23 2 Image failure 1 2 3 4 5 6 7 8 9 10 11 12 13 14 ...
Page 280: ...Confidential 9 24 15 a 15 b 16 17 18 19 20 21 22 23 24 25 Fig 9 1 ...
Page 325: ...App 1 5 Confidential 6 Transfer Unit X X X X X X 7 1 2 3 Location SERIAL NO YEAR MONTH DATE ...
Page 398: ...B Power Supply PCB 100V 127V Confidential ...