13. CHANGING SPECIAL FUNCTIONS USING THE MEMORY SWITCHES
56
KE-434C,435C
<Memory switches 10 - 1F>
Initial value
Switch
Motion when set to ON
Solenoid
Pneumatic
memo-10
−
--
--
memo-11
ON when a two-stage tensioner is used.
(Special order device that outputs from option output No. 1)
(Normally the tension opens when output is OFF, and the tension closes when
option output No. 1 is ON)
--
--
memo-12
Pneumatic wiper can be used.
(Special order device that outputs from option output No. 2)
--
--
memo-13
The inner clamping device moves forward at the 1/4-way mark and returns at the
3/4-way mark for the pattern being sewn.
(The device does not retract at this time, regardless of the setting for memo-15.)
--
--
memo-14
Solenoid wiper can be used.
--
ON
memo-15
When using the inner clamping device, shunting to prevent interference between
the inner clamping device and the needle is not carried out after the sewing end.
--
--
memo-16
Needle cooler can be used. (available by special order).
--
--
memo-17
Thread take-up device is not operated at the sewing end.
--
--
memo-18
Thread take-up device operates one stitch before the sewing end.
--
--
memo-19
For solenoid specifications, presser position errors are not detected.
--
--
memo-1A
Needle up stop position errors are not detected.
--
--
memo-1b
Presser can be moved up and down before the home position is detected.
(Normally the presser cannot be moved up and down until after the home position
has been detected.)
--
--
memo-1c
−
--
--
memo-1d
For pneumatic specifications, the air pressure detection switch is enabled.
(The air pressure sensor is a special-order option.)
--
--
memo-1E
Errors can be reset using the EMERGENCY STOP switch.
--
--
memo-1F
Thread is not trimmed when an emergency stop occurs during sewing.
--
--
-- : OFF
<Memory switches 20 - 2F>
Initial value
Switch
Motion when set to ON
Solenoid
Pneumatic
memo-20
−
--
--
memo-21
Rotating-type thread breakage detector operates.
(Device is available by special order.)
--
--
memo-22
During thread breakage detection, sensitivity is decreased from 8 to 14 stitches at
the sewing start. (Sensitivity during sewing is three stitches.)
--
--
memo-23
When DIP switch A-8 is simultaneously ON, setting values changed using the
operation panel are ignored.
--
--
memo-24
−
--
--
memo-25
−
--
--
memo-26
Enables the fiber-type thread breakage detector (when memo-21 is ON)
--
--
memo-27
−
--
--
memo-28
Stores the amount of parallel movement in memory.
(Use the memory all clear operation to clear the setting.)
--
--
memo-29
-
memo-2F
−
--
--
-- : OFF