3. INSTALLATION
9
KE-434C,435C
3-10. Installing the operation panel
The operation panel can be installed to either the top or bottom of the work table.
1. Install the rear frame (1) to the work table (top or bottom) with the four wood screws (2).
* At this time, tighten the wood screws (2) until the thickness of the rubber sheet is 2 to 2.5 mm.
2. Install the front frame (3) to the rear frame (1) with the four screws (4).
* The vertical orientation of the front frame (3) is the same whether it is installed to the top or the bottom of the work table.
3. Insert the connector cord (5) into the control box through the hole at the side of the box. Refer to “3-12. Connecting the cords” for
details on connecting the cord.
4. Secure the connector cord (5) with the staples (in three places).
3-11. Connecting the ground wire
CAUTION
Be sure to connect the ground. If the ground connection is not secure, you run the risk of receiving a serious electric shock,
and problems with correct operation may also occur.
2499Q
2500Q
0419Q
Top of work table
Bottom of work table
Table
Table
Rubber sheet
2 - 2.5mm
2741Q
Connect to the power switch. However, the
black wire is insulated to the inside of the
box and is not used.
Connect to ground