4. FUNCTION SETTINGS
20
KE-430F, BE-438F
No.
Setting range
Initial value
Setting units
Setting details
582 ON/OFF
ON
1
Upper thread tension tightening at the sewing start
ON: Enabled
OFF: Disabled
583
-150
−
150
(degrees)
0 5
Upper thread tension change (tightening) angle offset at the
sewing start
584
-110
−
40
(degrees)
0
5
Upper thread tension release angle offset at the sewing end
585
0
−
500
470
1
Upper thread tension value (tightening) at the sewing start
587
0
−
300
0
1
Upper thread tension value (release) at the sewing start
588
0
−
50
(ms)
35
1
Thread trimmer solenoid ON timing
589
0
−
50
(ms)
20
1
Thread trimmer solenoid ON time
590
5
−
10
5
1
Thread trimmer solenoid holding force
430F: 270
591
0
−
300
(degrees)
438F: 260
5 Specified
final
speed output angle offset
592
200
−
700
(sti/min)
600
100
Last stitch sewing speed for upper shaft motor
593
0
−
15
(ms)
8 1
Speed change delay until thread nipper operation is complete
* If the thread nipper device is not to operate, set to “0”.
594
-160
−
20
(degrees)
0
5
Needle up stop signal output angle offset
Error processing settings (600
−
699)
No. Setting
range
Initial
value
Setting units
Setting details
650
*1
*2
0
−
2
0 1
Error release method when operation has stopped
0: Press the RESET key on the operation panel.
1: Press the STOP switch (available by special order).
2: Press the external input switch (EXIN2).
651
*2
ON/OFF OFF -
Needle stop position when sewing is interrupted by the STOP
switch (available by special order)
ON: Needle stops in the up position.
OFF: Needle stops in the down position.
652
*2
ON/OFF OFF -
Thread trimming operation when sewing is paused
ON: Thread trimming is not carried out when the pause is
canceled.
OFF: Thread trimming is carried out when the pause is
canceled.
654
*2
ON/OFF OFF -
Use of STOP switch (available by special order)
ON: Used
OFF: Not used
655 ON/OFF OFF -
Disables needle up stop position monitoring.
ON: Disabled
OFF: Enabled (If the needle up stop position is incorrect, “UP”
will be displayed.)
657
OFF, 2
−
30
(seconds)
OFF 2
Time from error occurring to buzzer stopping
OFF: Buzzer does not stop.
2 – 30: Buzzer stops after the specified time.
*1: This is not initialized during initialization mode.
*2: These functions can be used if the main PCB version is 1.5.00 or later.
Summary of Contents for KE-430F Series
Page 45: ...5 EDITING PATTERN DATA 35 KE 430F BE 438F 5 2 Work flowchart 2922B ...
Page 149: ...15 ELECTRIC MECHANISM 139 KE 430F BE 438F Power PCB Panel PCB 2932B 2687B ...
Page 155: ...15 ELECTRIC MECHANISM 145 KE 430F BE 438F 2953B ...
Page 156: ...15 ELECTRIC MECHANISM 146 KE 430F BE 438F 2954B ...
Page 157: ...15 ELECTRIC MECHANISM 147 KE 430F BE 438F 2955B ...
Page 181: ...18 7 SEGMENT DISPLAY LIST 171 KE 430F BE 438F 18 7 SEGMENT DISPLAY LIST 4268M ...
Page 182: ...MEMO 172 KE 430F BE 438F ...
Page 183: ...MEMO 173 KE 430F BE 438F ...