<X and Y parallel movement amounts>
* When memory switch No. 465 is set to “3”, the following parameters are displayed during program mode and sewing
standby mode.
Item
Setting range
and initial value
Display during program mode
Display during sewing standby mode
X parallel
movement
amount
-9.9
−
9.9mm
Setting units: 0.1mm
(Initial setting is 0.0mm)
+ direction:
Work clamp/button
clamp moves to
the left.
Y parallel
movement
amount
-9.9
−
9.9mm
Setting units: 0.1mm
(Initial setting is 0.0mm)
+ direction:
Work clamp/button
clamp moves
forward.
2784B
2785B
2786B
2787B
Initial value
Initial value