15. ELECTRIC MECHANISM
156
KE-430F, BE-438F
Error status #8 Error code appears on the display when the foot switch is depressed.
Probable causes
Check/ repair/ adjust
Parts to be replaced
1. If the work clamp pulse motor
does not operate and "E300" is
displayed, there is a malfunction of
the power PCB.
Disconnect connectors P1 (POWER2) and P24
(POWER1) from the main PCB, and then turn on
the power switch and check LD1 (red) on the
power PCB.
OK if illuminated.
After checking, turn off the power switch, wait for
one minute or more, and then insert P1 and P24
into the main PCB.
Power PCB assembly
2. If the work clamp pulse motor
does not move and "E300" is
displayed, there is a malfunction of
the main PCB.
a. Disconnect connector P24 (POWER1) from
the main PCB, and check the continuity
between terminals 1 and 2 of P24.
OK if
∞
ohms.
b. Disconnect connector P23 (PPM) from the
main PCB, and check the continuity between
terminals 1 and 2, 3 and 4 of P23.
OK if
∞
ohms.
c. Insert P23 and P24 into the main PCB, turn on
the power switch and then check LD1 (red) on
the power PCB.
OK if illuminated.
If LD1 is illuminated during the check in step 1
but it does not illuminate when P1 and P24
are connected, there is a malfunction of the
main PCB.
d. Check LD1 (orange) on the main PCB.
OK if illuminated.
Main PCB assembly
3. If the work clamp pulse motor
moves slightly and "E300" is
displayed, there is a malfunction of
the encoder.
a. Check that connector P19 (P-ENC) is inserted
into the main PCB and that the color matches.
b. Check the encoder input while referring to
"4-7. Input checking method".
Pulse motor P assembly
Main PCB assembly
4. If the work clamp pulse motor
does not move and "E300" is
displayed, there is a malfunction of
the pulse motor and cord.
a. Disconnect the main PCB connector P23
(PPM) and measure the resistance between
pins 1-2 and 3-4 of the cord connector.
OK if 2-3 ohms.
b. If step a. (above) is OK, there is a malfunction
of the main PCB.
Pulse motor P assembly
Main PCB assembly
2717B
2722B
2723B
Summary of Contents for KE-430F Series
Page 45: ...5 EDITING PATTERN DATA 35 KE 430F BE 438F 5 2 Work flowchart 2922B ...
Page 149: ...15 ELECTRIC MECHANISM 139 KE 430F BE 438F Power PCB Panel PCB 2932B 2687B ...
Page 155: ...15 ELECTRIC MECHANISM 145 KE 430F BE 438F 2953B ...
Page 156: ...15 ELECTRIC MECHANISM 146 KE 430F BE 438F 2954B ...
Page 157: ...15 ELECTRIC MECHANISM 147 KE 430F BE 438F 2955B ...
Page 181: ...18 7 SEGMENT DISPLAY LIST 171 KE 430F BE 438F 18 7 SEGMENT DISPLAY LIST 4268M ...
Page 182: ...MEMO 172 KE 430F BE 438F ...
Page 183: ...MEMO 173 KE 430F BE 438F ...