Error status #5 Error code appears on the display when the foot switch is depressed.
Probable causes
Check/ repair/ adjust
Parts to be replaced
1. If “E130”, “E131” or “E132” is
displayed, there is a poor
connection of the synchronizer.
Refer to inspection #2-4.
2. If “E130”, “E131” or “E132” is
displayed, there is a poor
connection of the machine motor.
Check the connection of the relay connector
between the machine motor and the motor PCB.
3. If “E130”, “E131” or “E132” is
displayed, there is a blown fuse.
a. Remove fuses F1 and F2 from the motor PCB
and check the continuity.
OK if there is continuity.
b. If fuse F1 or F2 is blown, check the resistance
values between each pin of the relay
connector between the machine motor and the
motor PCB and between each terminal of the
fuses.
OK if
∞
ohms.
c. If the fuses blow again after they are replaced,
replace the motor PCB.
GFUSE15A
(15A-250V)
Motor PCB assembly
4. If “E130”, “E131” or “E132” is
displayed, there is a malfunction of
the motor PCB.
a. Check the synchronizer input while referring to
“4-7. Input checking method”.
OK if the signal turns on and off.
b. If step a. (above) is OK, there is a malfunction
of the motor PCB.
Resolver stator 430 assembly
Motor PCB assembly
Summary of Contents for KE-430F Series
Page 45: ...5 EDITING PATTERN DATA 35 KE 430F BE 438F 5 2 Work flowchart 2922B ...
Page 149: ...15 ELECTRIC MECHANISM 139 KE 430F BE 438F Power PCB Panel PCB 2932B 2687B ...
Page 155: ...15 ELECTRIC MECHANISM 145 KE 430F BE 438F 2953B ...
Page 156: ...15 ELECTRIC MECHANISM 146 KE 430F BE 438F 2954B ...
Page 157: ...15 ELECTRIC MECHANISM 147 KE 430F BE 438F 2955B ...
Page 181: ...18 7 SEGMENT DISPLAY LIST 171 KE 430F BE 438F 18 7 SEGMENT DISPLAY LIST 4268M ...
Page 182: ...MEMO 172 KE 430F BE 438F ...
Page 183: ...MEMO 173 KE 430F BE 438F ...