Revision C 16/01/96
Chapter 2 "PCL" - 97
Set Status Readback Location Type
ESC*s#T
(27)(42)(115)#(84)
<1Bh><2Ah><73h>#<54h>
This command determines the status location type to the value of #.
The location type is used in association with the location unit in order to specify an entity location for a status
request.
•
#=0 specifies an invalid location. When the printer receives an Inquire Entity Command, an error response is
generated. This is the default value. When you execute a printer reset, this value is reset to 0.
•
•
# = 1 specifies the currently selected location.
•
•
# = 2 specifies all locations.
•
•
# = 3 specifies the printer's internal location.
•
•
# = 4 specifies the downloaded entity.
•
•
# = 5 specifies the user-installed card/cartridge
The location type setting is retained by the printer. When the printer does not send the set status readback location
type command in order to change the setting for an entity request, then the printer uses the currently available
location type setting.
Set Status Readback Location Unit
ESC*s#U
(27)(42)(115)#(85)
<1Bh><2Ah><73h>#<55h>
•
The status location unit is selected by the value of #.
•
The printer uses the location unit in association with the location type in order to specify an entity location for
a status request.
Type
Unit
0
-
invalid location
1
-
currently selected location
2
-
all locations
3
0
all internal entities
4
0
1
2
all downloaded entities
downloaded entity as temporary
downloaded entity as permanent
5
0
1
n
All cartridge/cards
the cartridge/card which has the highest
priority.
the cartridge/card which has the lowest
priority
•
When the location value is 0, 1 and 2, it ignores the unit value which might be set to any value. The default
value is 0, and whenever you reset the printer, the value is reset to default value.
•
The location unit setting is retained by the printer. If the printer does not send this command to change the
setting for an entity request, then it uses the currently available location units.
•
The printer may set the location type and unit in order. It does not identify any invalid combinations until it
receives the inquire entity command. Hence, if the unit value is not in the correct range, it sets the unit to the
value for a proper error response to be sent when the inquire entity command is received.
Summary of Contents for HL- SERIES
Page 13: ...Revision A 16 01 96 Chapter 1 Introduction ...
Page 16: ...Revision C 16 01 96 Chapter 2 PCL 1 Chapter 2 PCL ...
Page 123: ...Revision C 16 01 96 Chapter 2 PCL 3 W width raster area 78 Y y offset raster 79 ...
Page 124: ...Revision C 16 01 96 Chapter 3 PJL 1 Chapter 3 PJL Printer Job Language ...
Page 180: ...Revision C 16 01 96 Chapter 4 Diablo 630 1 Chapter 4 Diablo 630 ...
Page 200: ...Revision C 16 01 96 Chapter 5 EPSON FX 850 1 Chapter 5 EPSON FX 850 ...
Page 237: ...Revision C 16 01 96 Chapter 6 IBM Proprinter XL 1 Chapter 6 IBM Proprinter XL ...
Page 259: ...Revision C 16 01 96 Chapter 7 Bar Codes Control 1 Chapter 7 Bar Code Control ...
Page 267: ...Revision C 16 01 96 Chapter 8 HP GL2 1 CHAPTER 8 HP GL 2 Graphics Language ...
Page 280: ...Revision C 16 01 96 Chapter 8 HP GL2 14 220 END Sample 21 ...
Page 328: ...Revision C 16 01 96 Chapter 9 HP GL 1 CHAPTER 9 HP GL Graphics Language ...
Page 342: ...Revision C 16 01 96 Chapter 9 HP GL 15 Sample 68 ...
Page 387: ...Revision C 16 01 96 APPENDIX A COMPALISON LIST 24 RESOLUTION 300 600 300 600 300 600 ...