2-59
Confidential
■
Error code 89
Unsupported paper size is used for duplex printing.
<User Check>
- Use the A4 or Letter size paper.
- Check if the thickness of the paper is 60 to 105 g/m
2
.
■
Error code 8A
Paper jam in the paper tray 1.
<User Check>
- Check if the paper is loaded into the paper tray 1 correctly.
- Turn back the paper loaded in the paper tray 1 or change the orientation of the paper by 180°.
- Adjust the paper guide corresponding to the paper size.
- Check if too much paper is loaded in the tray.
- Check if the thickness of the paper is 60 to 105 g/m
2
.
Size Error DX
Specify the correct paper and press Go.
Step
Cause
Remedy
1
Registration front/rear sensor
PCB failure
Check the registration front/rear sensor
performance following the procedure
described in
. If any
problem is found, replace the registration
front/rear sensor PCB ASSY.
2
Engine PCB failure
Replace the engine PCB ASSY.
3
Main PCB failure
Replace the main PCB ASSY.
Jam Tray 1
Remove the jammed paper from Tray 1.
Step
Cause
Remedy
1
Foreign object around paper tray
1
Remove the foreign object.
2
Harness connection failure of T1
registration front/rear sensor
PCB ASSY
Check the harness connection of the
T1 registration front/rear sensor PCB
ASSY and reconnect it.
3
Paper feeding kit1 worn out
Replace the paper feeding kit1.
4
Registration front actuator
malfunction
Re-assemble the registration front
actuator.
5
Registration front sensor failure
Check the sensor performance following
the procedure described in
. If any problem occurs, replace the T1
registration front/rear sensor PCB ASSY.
6
Engine PCB failure
Replace the engine PCB ASSY.
7
Main PCB failure
Replace the main PCB ASSY.
Summary of Contents for HL-4140CN
Page 19: ...Confidential CHAPTER 1 SPECIFICATIONS ...
Page 29: ...Confidential CHAPTER 2 ERROR INDICATION AND TROUBLESHOOTING ...
Page 145: ...Confidential CHAPTER 3 DISASSEMBLY AND ASSEMBLY ...
Page 169: ...3 21 Confidential 8 DISASSEMBLY FLOW Disassembly Re Assembly second ...
Page 296: ...Confidential CHAPTER 4 ADJUSTMENTS AND UPDATING OF SETTINGS REQUIRED AFTER PARTS REPLACEMENT ...
Page 311: ...Confidential CHAPTER 5 SERVICE FUNCTIONS ...
Page 336: ...5 23 Confidential Inter color position alignment adjustment chart Fig 5 8 ...
Page 343: ...5 30 Confidential Fig 5 11 ...
Page 345: ...5 32 Confidential Fig 5 12 First side Second side ...
Page 347: ...5 34 Confidential Color test pattern Fig 5 13 MCYK Y C K M YCMK_ _A ...
Page 354: ...5 41 Confidential Maintenance information Fig 5 14 ...
Page 382: ...Confidential CHAPTER 6 CIRCUIT DIAGRAMS WIRING DIAGRAM ...
Page 384: ...6 1 Confidential 1 CIRCUIT DIAGRAMS High voltage Power Supply PCB Circuit Diagram 1 3 ...
Page 385: ...6 2 Confidential High voltage Power Supply PCB Circuit Diagram 2 3 ...
Page 386: ...6 3 Confidential High voltage Power Supply PCB Circuit Diagram 3 3 ...
Page 387: ...6 4 Confidential Low voltage Power Supply PCB Circuit Diagram 100V ...
Page 388: ...6 5 Confidential Low voltage Power Supply PCB Circuit Diagram 200V ...
Page 389: ...6 6 Confidential 2 WIRING DIAGRAM Wiring Diagram ...
Page 390: ...Confidential CHAPTER 7 PERIODICAL MAINTENANCE ...
Page 424: ...Confidential APPENDIX 1 SERIAL NUMBERING SYSTEM ...
Page 428: ...Confidential APPENDIX 3 INSTALLING THE MAINTENANCE DRIVER ...
Page 432: ...App 3 4 Confidential 10 Alert warning message appears click Continue Anyway to proceed ...