Confidential
1-34
Error code CC
No Fuser Unit
Install the Fuser Unit.
Fuser unit is not installed into the machine.
User Check
- Check if the fuser unit is installed into the machine.
Step
Cause
Remedy
1
Harness connection failure
between fuser unit connector
and engine PCB
Check the harness connection between the fuser
unit connector and engine PCB, and reconnect it.
2
Engine PCB failure
Replace the engine PCB ASSY.
3
Main PCB failure
Replace the main PCB ASSY.
Error code CD
No Drum Unit
Install the Drum Unit.
Drum unit is not installed into the machine.
User Check
- Check if the drum unit is installed into the machine.
Step
Cause
Remedy
1
Dirt on electrodes on drum
unit and front door unit ASSY
Clean both electrodes.
(Refer to
Fig. 1-2
and
Fig 1-3 (P 1-35)
.)
2
Bending of front door unit
ASSY electrode contact
Correct the electrode bending of the front door unit
ASSY.
3
Harness connection failure
between front door unit ASSY
electrode and engine PCB
ASSY
Check the harness connection between the front
door unit ASSY electrode and engine PCB ASSY.
4
Engine PCB failure
Replace the engine PCB ASSY.
Summary of Contents for HL-4040CN
Page 265: ...Confidential 4 7 11 Alert warning message of WHQL appears Click Continue Anyway to proceed ...
Page 320: ...Confidential 6 12 Charge High voltage Power Supply PCB Circuit Diagram 1 4 ...
Page 321: ...Confidential 6 13 Charge High voltage Power Supply PCB Circuit Diagram 2 4 ...
Page 322: ...Confidential 6 14 Charge High voltage Power Supply PCB Circuit Diagram 3 4 ...
Page 323: ...Confidential 6 15 Charge High voltage Power Supply PCB Circuit Diagram 4 4 ...
Page 324: ...Confidential 6 16 Transfer High voltage Power Supply PCB Circuit Diagram 1 2 ...
Page 325: ...Confidential 6 17 Transfer High voltage Power Supply PCB Circuit Diagram 2 2 ...
Page 326: ...Confidential 6 18 Low voltage Power Supply PCB Circuit Diagram 100V ...
Page 327: ...Confidential 6 19 Low voltage Power Supply PCB Circuit Diagram 200V ...