1.4.5 Operational Check of Control Panel PCB (Function code 13)
<Function>
This function allows you to check the control panel PCB for normal operation.
<Operating Procedure>
(1) Press
the or button to display “MAINTENANCE 13” on the LCD in the initial stage of
the maintenance mode. Then, press the
OK
button.
The machine displays “00” on the LCD.
(2) Press the buttons in the order designated in the illustration shown below.
The LCD shows the corresponding number in decimal notation each time a button is
pressed. Check that the displayed number is correct by referring to the illustration below.
If a button is pressed out of order, the machine displays the "INVALID OPERATE" on the
LCD. To return to the status ready to accept button entry for operational check, press the
Cancel
button.
(3) After the last number button is pressed, the machine beeps and returns to the initial stage
of the maintenance mode.
To terminate this operation, press the
Cancel
button. The machine returns to the initial
stage of the maintenance mode.
1
2
3
4
5
7
8
6
Fig. 5-4
Summary of Contents for HL-4040CN
Page 265: ...Confidential 4 7 11 Alert warning message of WHQL appears Click Continue Anyway to proceed ...
Page 320: ...Confidential 6 12 Charge High voltage Power Supply PCB Circuit Diagram 1 4 ...
Page 321: ...Confidential 6 13 Charge High voltage Power Supply PCB Circuit Diagram 2 4 ...
Page 322: ...Confidential 6 14 Charge High voltage Power Supply PCB Circuit Diagram 3 4 ...
Page 323: ...Confidential 6 15 Charge High voltage Power Supply PCB Circuit Diagram 4 4 ...
Page 324: ...Confidential 6 16 Transfer High voltage Power Supply PCB Circuit Diagram 1 2 ...
Page 325: ...Confidential 6 17 Transfer High voltage Power Supply PCB Circuit Diagram 2 2 ...
Page 326: ...Confidential 6 18 Low voltage Power Supply PCB Circuit Diagram 100V ...
Page 327: ...Confidential 6 19 Low voltage Power Supply PCB Circuit Diagram 200V ...