![Brother HL-4040CN Service Manual Download Page 26](http://html.mh-extra.com/html/brother/hl-4040cn/hl-4040cn_service-manual_53642026.webp)
Confidential
1-9
Error code C9
DIMM Error
Make sure that the DIMM is inserted correctly.
Defective DIMM is installed.
User Check
- Check if the DIMM is installed correctly.
- Replace the DIMM with a new one.
Error code E0
Print Unable E0
Turn the power off and then back on again.
Program error
User Check
- Turn the power off and on.
Error code E1
Print Unable E1
Turn the power off and then back on again.
Program error
User Check
- Turn the power off and on.