Confidential
3-66
(2) Disconnect the Connector (CN35) from the Engine PCB ASSY.
CN35
Fig. 3-80
(3) Remove the one cup S M3x6 Taptite screw, and then remove the THM/HUM ground plate.
(4) Remove the four cup S M3x6 Taptite screws.
(5) Release the two Hooks to remove the THM/HUM sensor holder ASSY.
Fig. 3-81
Engine PCB ASSY
Taptite, cup S M3x6
Taptite, cup S M3x6
Hook
Hook
THM/HUM sensor
holder ASSY
Frame unit
<Left side>
THM/HUM ground plate