(10) Remove the two screws and take off the flat cable clamp.
(11) To take out the panel harness, remove sponges F and R that are backed with adhesive tape.
NOTE: Once removed, those sponges will become unusable and new parts will have to be put
back in.
(12) To take out the CCD flat cable, remove sponge R.
n
Reassembling Notes
• When replacing the CCD unit with a new one, you need to attach a CCD protector to it as
specified on page 4-28. A new CCD protector is covered with a protection sheet, so remove the
protection sheet before attaching.
• When using a new CCD flat cable, fold it and secure it to the scanner base with double-sided
adhesive tape and sponge R (backed with adhesive tape) as illustrated above.
Then attach it to the underside of the CCD unit with double-sided adhesive tape.
• When reassembling the components inside the scanner unit, use screws (Taptite, cup B M3x8).
Never use longer ones (e.g., M3x10). Using longer ones will bore a hole in the scanner base.
• When installing the CCD drive belt to the scanner base, set its rear end within the range
specified on page 4-27.
Summary of Contents for DCP-1000
Page 1: ...Multi Function Machine SERVICE MANUAL MODEL MFC6800 DCP1000 MFC9180 MFC9160 ...
Page 5: ...CHAPTER 1 GENERAL DESCRIPTION ...
Page 12: ...CHAPTER 2 INSTALLATION ...
Page 17: ...CHAPTER 3 THEORY OF OPERATION ...
Page 19: ...3 1 3 1 OVERVIEW Provided on models supporting facsimile function ...
Page 21: ...3 3 ...
Page 29: ...3 11 Location of Sensors and Actuators ...
Page 31: ...CHAPTER 4 DISASSEMBLY REASSEMBLY AND LUBRICATION ...
Page 38: ...4 5 n Disassembly Order Flow ...
Page 70: ...4 37 6 Turn the ASF upside down then remove the registration sensor actuator ...
Page 78: ...4 45 Setting up the main PCB after replacement ...
Page 104: ...CHAPTER 5 MAINTENANCE MODE ...
Page 111: ...5 6 Scanning Compensation Data List ...
Page 119: ...5 13 For machines w fax For machines w o fax Key Button Entry Order ...
Page 126: ...CHAPTER 6 ERROR INDICATION AND TROUBLESHOOTING ...
Page 156: ...MFC6800 DCP1000 MFC9180 MFC9160 Appendix 1 EEPROM Customizing Codes ...
Page 159: ...MFC6800 DCP1000 MFC9180 MFC9160 Appendix 2 Firmware Switches WSW ...
Page 206: ...A Main PCB 1 5 ...
Page 207: ...A Main PCB 2 5 ...
Page 208: ...A Main PCB 3 5 ...
Page 209: ...A Main PCB 4 5 ...
Page 210: ...A Main PCB 5 5 ...
Page 211: ...B NCU PCB U S A Canada ...
Page 212: ...B NCU PCB U K Norway Netherlands Finland Denmark Sweden ...
Page 213: ...B NCU PCB Germany France Belgium Switzerland Ireland Austria Spain Italy South Africa ...
Page 214: ...B NCU PCB Asia Oceania 1 2 ...
Page 216: ...C Control Panel PCB ...
Page 217: ...D Power Supply PCB 100 120V Low voltage power supply ...
Page 218: ...D Power Supply PCB 200 240V Low voltage power supply Europe ...
Page 219: ...D Power Supply PCB 200 240V Low voltage power supply Asia Oceania ...
Page 220: ...D Power Supply PCB High voltage power supply ...
Page 221: ...E Relay PCB ...