6-12
(9) Signal isolation
Code 1
Code 2
Causes
90
01
Unable to detect video signals and commands within 6 seconds
after CFR is transmitted.
90
02
Received PPS containing invalid page count or block count.
(10) Video signal reception
Code 1
Code 2
Causes
A0
03
Error correction sequence not terminated even at the final
transmission speed for fallback.
A0
11
Receive buffer empty. (5-second time-out)
A0
12
Receive buffer full during operation except receiving into
memory.
A0
13
Decoding error continued on 500 lines.
A0
14
Decoding error continued for 10 seconds.
A0
15
Timeout: Five seconds or more for one-line transmission.
A0
16
RTC not found and carrier OFF signal detected for 6 seconds.
A0
17
RTC found but no command detected for 60 seconds.
A0
18
Receive buffer full during receiving into memory.
A0
19
Unable to obtain compressed image data to be sent in phase C.
A8
01
RTN, PIN, or ERR received at the calling terminal.*
A9
01
RTN, PIN, or ERR received at the called terminal.*
* Available in German versions only
Summary of Contents for DCP-1000
Page 1: ...Multi Function Machine SERVICE MANUAL MODEL MFC6800 DCP1000 MFC9180 MFC9160 ...
Page 5: ...CHAPTER 1 GENERAL DESCRIPTION ...
Page 12: ...CHAPTER 2 INSTALLATION ...
Page 17: ...CHAPTER 3 THEORY OF OPERATION ...
Page 19: ...3 1 3 1 OVERVIEW Provided on models supporting facsimile function ...
Page 21: ...3 3 ...
Page 29: ...3 11 Location of Sensors and Actuators ...
Page 31: ...CHAPTER 4 DISASSEMBLY REASSEMBLY AND LUBRICATION ...
Page 38: ...4 5 n Disassembly Order Flow ...
Page 70: ...4 37 6 Turn the ASF upside down then remove the registration sensor actuator ...
Page 78: ...4 45 Setting up the main PCB after replacement ...
Page 104: ...CHAPTER 5 MAINTENANCE MODE ...
Page 111: ...5 6 Scanning Compensation Data List ...
Page 119: ...5 13 For machines w fax For machines w o fax Key Button Entry Order ...
Page 126: ...CHAPTER 6 ERROR INDICATION AND TROUBLESHOOTING ...
Page 156: ...MFC6800 DCP1000 MFC9180 MFC9160 Appendix 1 EEPROM Customizing Codes ...
Page 159: ...MFC6800 DCP1000 MFC9180 MFC9160 Appendix 2 Firmware Switches WSW ...
Page 206: ...A Main PCB 1 5 ...
Page 207: ...A Main PCB 2 5 ...
Page 208: ...A Main PCB 3 5 ...
Page 209: ...A Main PCB 4 5 ...
Page 210: ...A Main PCB 5 5 ...
Page 211: ...B NCU PCB U S A Canada ...
Page 212: ...B NCU PCB U K Norway Netherlands Finland Denmark Sweden ...
Page 213: ...B NCU PCB Germany France Belgium Switzerland Ireland Austria Spain Italy South Africa ...
Page 214: ...B NCU PCB Asia Oceania 1 2 ...
Page 216: ...C Control Panel PCB ...
Page 217: ...D Power Supply PCB 100 120V Low voltage power supply ...
Page 218: ...D Power Supply PCB 200 240V Low voltage power supply Europe ...
Page 219: ...D Power Supply PCB 200 240V Low voltage power supply Asia Oceania ...
Page 220: ...D Power Supply PCB High voltage power supply ...
Page 221: ...E Relay PCB ...