
43
WSW44
(Speeding up scanning-1)
Selector
No.
Function
Setting and Specifications
1
|
5
Not used.
6
|
8
Effective time length of the white
level compensation data obtained
beforehand
No. 6 7 8
0 0 0 : Obtained compensation data
ineffective
0 0 1 :
1 min.
0 1 0 :
3 min.
0 1 1 :
5 min.
1 0 0 :
10 min.
1 0 1 :
15 min.
1 1 0 :
20 min.
1 1 1 :
30 min.
NOTE:
WSW44 is applicable only to models equipped with a flat-bed scanner.
Selectors 6 through 8: Effective time length of the white level compensation data obtained
beforehand
If you set documents in the ADF and the document front sensor detects them or if you open the
document tray ASSY and the document tray open sensor detects the open state, then the controller
will make correction of the reference voltage to be applied to white level compensation for
document scanning before the Copy button is pressed.
These selectors determine how long compensation data obtained beforehand will keep effective.
Summary of Contents for DCP-1000
Page 1: ...Multi Function Machine SERVICE MANUAL MODEL MFC6800 DCP1000 MFC9180 MFC9160 ...
Page 5: ...CHAPTER 1 GENERAL DESCRIPTION ...
Page 12: ...CHAPTER 2 INSTALLATION ...
Page 17: ...CHAPTER 3 THEORY OF OPERATION ...
Page 19: ...3 1 3 1 OVERVIEW Provided on models supporting facsimile function ...
Page 21: ...3 3 ...
Page 29: ...3 11 Location of Sensors and Actuators ...
Page 31: ...CHAPTER 4 DISASSEMBLY REASSEMBLY AND LUBRICATION ...
Page 38: ...4 5 n Disassembly Order Flow ...
Page 70: ...4 37 6 Turn the ASF upside down then remove the registration sensor actuator ...
Page 78: ...4 45 Setting up the main PCB after replacement ...
Page 104: ...CHAPTER 5 MAINTENANCE MODE ...
Page 111: ...5 6 Scanning Compensation Data List ...
Page 119: ...5 13 For machines w fax For machines w o fax Key Button Entry Order ...
Page 126: ...CHAPTER 6 ERROR INDICATION AND TROUBLESHOOTING ...
Page 156: ...MFC6800 DCP1000 MFC9180 MFC9160 Appendix 1 EEPROM Customizing Codes ...
Page 159: ...MFC6800 DCP1000 MFC9180 MFC9160 Appendix 2 Firmware Switches WSW ...
Page 206: ...A Main PCB 1 5 ...
Page 207: ...A Main PCB 2 5 ...
Page 208: ...A Main PCB 3 5 ...
Page 209: ...A Main PCB 4 5 ...
Page 210: ...A Main PCB 5 5 ...
Page 211: ...B NCU PCB U S A Canada ...
Page 212: ...B NCU PCB U K Norway Netherlands Finland Denmark Sweden ...
Page 213: ...B NCU PCB Germany France Belgium Switzerland Ireland Austria Spain Italy South Africa ...
Page 214: ...B NCU PCB Asia Oceania 1 2 ...
Page 216: ...C Control Panel PCB ...
Page 217: ...D Power Supply PCB 100 120V Low voltage power supply ...
Page 218: ...D Power Supply PCB 200 240V Low voltage power supply Europe ...
Page 219: ...D Power Supply PCB 200 240V Low voltage power supply Asia Oceania ...
Page 220: ...D Power Supply PCB High voltage power supply ...
Page 221: ...E Relay PCB ...