Error code E 12X (where X is the configured CANopen input)
Error code E 13X (where X is the configured CANopen input)
Error
An SRDO communication (CANopen Safety) error has
occurred.
Possible
causes
1. Cable between sensor and electronics is damaged or
not connected.
2. Electrical faults on the CANopen line.
3. Damage to the sensor itself.
4. The electronics platform (0656) is damaged.
Possible
remedy
1. Check the cables and connections. Replace if
necessary.
2. Sensor replacement.
3. Exchange of electronics.
Error
CANopen sensor reports a detected error with the help of
an emergency message.
Possible
causes
1. See CANopen sensor error table.
Possible
remedy
1. Check the sensor.
2. Sensor replacement.