Section 1 Introduction
Brooks
®
Ar-Mite
TM
MT3750C
Brooks
®
Ar-Mite
TM
MT3750C
2
Table 1-1 MT3750C Specifications
Table 1-2 MT3750C Capacities
Specifications
MT3750C
Measuring Range
See Capacities Table 1-2
Rangeability
10:1 (most sizes)
Metering
Tube
316L
(stainless
steel)
Monel K-500
End Fittings
316L (stainless steel)
Monel K-500
Accuracy
5%, 3%, VDI/VDE class 4, 2.5
Repeatability
1% Full Scale
Scale
Silver increments with black background - Aluminum Material (52 mm long), single or dual
Connections
1/4” to 3/4”NPT Female
1/4”, 6 mm tube compression
Floats
316L stainless steel
Titanium Gr. II
O-rings
Viton
®
fluoroelastomers
PTFE Teflon
®
, Buna-N, Kalrez
®
4079 perfluoroelastomers, Ethylene Propylene
Protection Category
(Alarms) IP65/NEMA 4X, (Transmitter) IP66/67/NEMA 4X
Indicator Housing & Cover
Die cast Aluminum (Alloy 380), epoxy paint, glass window
Maximum Fluid Temperature
204°C/400°F (Refer to Tables 1-4 & 1-5)
Maximum Fluid Pressure
1500 PSIG (100 Bar)
4000 PSIG (276 Bar) (No valve, 1/4” NPT only)
Meter Dimensions
Refer to Figures on Pages 1-8 thru 1-11
Pressure Equipment Directive
Flowmeter complies under Sound Engineering Practices (SEP)
(PED) 2014/68/EU
RoHS
Products conform to the European Restriction of Hazardous Substances (RoHS) Directive 2011/65/EU
Inductive Alarm Switches
1 or 2 inductive switches
Reed Switches
1 or 2 switches
Transmitter
4-20 mA output
Agency Approvals
Refer to Tables 1-6 thru 1-9
Optional Equipment
Cartridge or NRS
TM
valves
Integrally mounted flow controllers
Meter
Meter
Meter
Meter
Meter
Flow Range
Flow Range
Flow Range
Flow Range
Flow Range
Viscosity
Viscosity
Viscosity
Viscosity
Viscosity
Pressure
Pressure
Pressure
Pressure
Pressure
Size
Size
Size
Size
Size
Water
Water
Water
Water
Water
Air
Air
Air
Air
Air
(1, 2)
(1, 2)
(1, 2)
(1, 2)
(1, 2)
Limit
Limit
Limit
Limit
Limit
(3)
(3)
(3)
(3)
(3)
Drop
Drop
Drop
Drop
Drop
gph
gph
gph
gph
gph
l/h
l/h
l/h
l/h
l/h
ln/h
ln/h
ln/h
ln/h
ln/h
scfh
scfh
scfh
scfh
scfh
m
m
m
m
m
33333
n/h
n/h
n/h
n/h
n/h
CP
CP
CP
CP
CP
mBar
mBar
mBar
mBar
mBar
Inches WC
Inches WC
Inches WC
Inches WC
Inches WC
0
0.025-0.25
0.096-0.96
4.3-43
0.16-1.6
-
5
12
4.8
1
0.034-0.34
0.13-1.3
5.6-56
0.21-2.1
-
10
12
4.8
2
0.096-0.96
0.36-3.6
13.0-120
0.5-4.9
-
20
12
4.8
3
0.29-2.8
1.0-10
-
1.2-12
0.033-0.33
35
12
4.8
4
0.55-5.5
2.1-21
-
2.5-23
0.063-0.62
70
32
12.8
5
1.1-11
4.2-42
-
5.4-53
0.15-1.3
100
38
15.3
6
2.8-26
11-100
-
12-110
0.31-3.1
130
44
17.7
Notes:
1. Air flows in scfh converted to 70°F and 14.7 psia when the meter is operated at 70°F and 14.7 psia.
2. Air flows in m
3
n/h (converted to normal conditions: 0° and 1.013 bar abs) when the meter is operated at 1.013 bar abs and 20°C.
3. When the viscosity of the fluid exceeds the viscosity immunity ceiling (VIC), a calculated correction is applied to account for the difference between factory calibration
fluid and process fluid.
Summary of Contents for Ar-Mite MT3750
Page 19: ...Section 2 Installation 15 Figure 2 3 Inductive Switch Wiring Brooks Ar MiteTM MT3750C...
Page 26: ...Section 2 Installation Brooks Ar MiteTM MT3750C 22 Figure 2 9 Transmitter Wiring Diagram...
Page 30: ...Section 3 Operation Brooks Ar MiteTM MT3750C 26 Figure 3 1 Reed Switch Alarm...
Page 34: ...Section 5 Parts List 30 Figure 5 1 Model MT3750 Exploded View Brooks Ar MiteTM MT3750C...