Section 2 Installation
Brooks
®
Ar-Mite
TM
MT3750C
13
Transit Precautions
To safeguard against damage during transit, transport the instrument to the
installation site in the same container used for transportation from the factory
if circumstances permit.
Removal From Storage
Upon removal of the instrument from storage, a visual inspection should be
conducted to verify its "as-received" condition.
If the instrument has been
subject to storage conditions in excess of those recommended (See Section
2-3), it should be subjected to a pneumatic pressure test in accordance with
applicable vessel codes.
Installation of Flowmeter
Recommended installation for Model MT 3750C is as follows:
A. Carefully remove the covers from each end of the flowmeter.
B. Install the flowmeter with the inlet at the bottom and the outlet at the
top.
C. When installing the flowmeter in the process line, follow accepted
plumbing practices for flanged or threaded fittings.
D. Install the flowmeter within 5° of true vertical. Use of a level is
recommended to determine the proper alignment.
E. Installation of a bypass piping arrangement is recommended, Refer
to Figure 2-1. Bypass piping permits the meter to be isolated from the
flow line for servicing and cleaning.
GENERAL NOTE FOR ELECTRONICS:
The Electrical connections shall be made in such a way that the degree
of ingress protection is maintaintained and is suitable for the installed
environment. See UL 50, NEMA 250 and EN 60529. Most installations will
require Type 4X or IP54 as a minimum installation.
Installation of Inductive Alarm
Summary of Contents for Ar-Mite MT3750
Page 19: ...Section 2 Installation 15 Figure 2 3 Inductive Switch Wiring Brooks Ar MiteTM MT3750C...
Page 26: ...Section 2 Installation Brooks Ar MiteTM MT3750C 22 Figure 2 9 Transmitter Wiring Diagram...
Page 30: ...Section 3 Operation Brooks Ar MiteTM MT3750C 26 Figure 3 1 Reed Switch Alarm...
Page 34: ...Section 5 Parts List 30 Figure 5 1 Model MT3750 Exploded View Brooks Ar MiteTM MT3750C...