S T E P O N E :
1. Shut off water supply.
2. Ensure that the sensor is not installed within 300mm of any adjacent surface. Do not
install the sensor facing a mirror or any other system operated by an infra-red sensor.
3. Install a ½” BSP female fitting in the wall for the outlet (not supplied) in the required
location/position. (Refer to the dimensions on the drawing for correct positioning).
4. Below the male thread, a cut out of 50mm x 80mm is required in the wall to recess the
sensor and sensor mounting bracket. This is to be 110mm from centre of male thread,
to centre of the sensor eye.
5. Feed the leads from the transformer and from the solenoid from inside the wall cavity
through to the front of the recess for the sensor. Connect the sensor to the leads (1x male
connection, 1x female connection).
6. Trial fit the spout nipple by screwing the spout nipple through the cover plate, and into the
female fitting in the wall. Press the spout onto the nipple. If there is a gap between the
back of the spout and cover plate, measure the gap and cut down themale thread on the
nipple to the desired length. Apply thread sealant or thread tape to the male thread of the
spout nipple, and screw the spout nipple into the female fitting in the wall.
7. Run a thin bead of silicone sealant on the inside face of the cover plate to seal the unit to
the wall. Press the plate into position on the wall.
8. Press and fit the spout onto the nipple. Set it into position, and lock into position using the
2 grub screws and allen key provided on the under side of the spout.
9. Turn on the water and power supply, and test for functionality. Adjustments to the sensor
range and run time are done by using the appropriate remote control (sold separately).
If there are any set up queries, please refer to the troubleshooting section in the back
of this booklet.
Note: If there is not enough length in either lead, do not cut or make your own lead. Modifying
or making your own lead will void warranty. Brodware have extension leads to suit (part
numbers are in the spare parts list at rear of this booklet). Please contact your supplier to
place your order.
C O N T I N U E T O P A G E 1 3 F O R F O L LO W I N G I N S T R U C T I O N S T O C O M P L E T E T H E I N S TA L L AT I O N
O F Y O U R B R O D W A R E S E N S O R TA P
O U T L E T A N D S E N S O R I N S TA L L AT I O N G U I D E F O R
2 . 2 7 0 5 . 7 0 A N D 2 7 0 6 . 7 0
Note: Use 32mm conduit to conceal wiring