background image

S T E P   O N E :

1.  Shut off water supply.
2.  Ensure that the sensor is not installed within 300mm of any adjacent surface. Do not  

 

install the sensor facing a mirror or any other system operated by an infra-red sensor.

3.  Install a ½” BSP female fitting in the wall for the outlet (not supplied) in the required  

 

location/position. (Refer to the dimensions on the drawing for correct positioning).

4.  Below the male thread, a cut out of 50mm x 80mm is required in the wall to recess the  

 

sensor and sensor mounting bracket. This is to be 110mm from centre of male thread,  

 

to centre of the sensor eye.

5.  Feed the leads from the transformer and from the solenoid from inside the wall cavity  

 

through to the front of the recess for the sensor. Connect the sensor to the leads (1x male  

 

connection, 1x female connection). 

6.  Trial fit the spout nipple by screwing the spout nipple through the cover plate, and into the  

 

female fitting in the wall. Press the spout onto the nipple. If there is a gap between the  

 

back of the spout and cover plate, measure the gap and cut down themale thread on the  

 

nipple to the desired length.  Apply thread sealant or thread tape to the male thread of the  

 

spout nipple, and screw the spout nipple into the female fitting in the wall.

7.  Run a thin bead of silicone sealant on the inside face of the cover plate to seal the unit to  

 

the wall. Press the plate into position on the wall. 

8.  Press and fit the spout onto the nipple. Set it into position, and lock into position using the  

 

2 grub screws and allen key provided on the under side of the spout. 

9.  Turn on the water and power supply, and test for functionality. Adjustments to the sensor  

 

range and run time are done by using the appropriate remote control (sold separately).  

 

If there are any set up queries, please refer to the troubleshooting section in the back  

 

of this booklet.

Note: If there is not enough length in either lead, do not cut or make your own lead. Modifying 

or making your own lead will void warranty. Brodware have extension leads to suit (part 

numbers are in the spare parts list at rear of this booklet). Please contact your supplier to  

place your order.

C O N T I N U E   T O   P A G E   1 3   F O R   F O L LO W I N G   I N S T R U C T I O N S   T O   C O M P L E T E   T H E   I N S TA L L AT I O N 
O F   Y O U R   B R O D W A R E   S E N S O R   TA P

O U T L E T   A N D   S E N S O R   I N S TA L L AT I O N   G U I D E   F O R 
2 . 2 7 0 5 . 7 0   A N D   2 7 0 6 . 7 0

Note: Use 32mm conduit to conceal wiring

11

12

Summary of Contents for 2.2702.90

Page 1: ...705 0 0 2 2705 02 2 2705 20 2 2705 22 2 2705 30 2 2705 70 2 2706 0 0 2 2706 02 2 2706 20 2 2706 22 2 2706 30 2 2706 70 2 2706 94 2 2702 90 2 2702 92 ELEC TRO N I C S EN SO R TAP I N STALL ATI O N MAI...

Page 2: ...ation of your sensor wall set After reading this manual if you still have any questions about the installation process or correct maintainance of the sensor wall set please call us on 61 1300 800 300...

Page 3: ...for gravity feed systems CO RREC T SOAP VI SCOS IT Y Ensure that the correct soap is selected for the Brosmart Sensor Soap Dispensers A soap with no grit and a viscosity of 100 3800cPs is to be used F...

Page 4: ...hrough from the rear of the Sensor Mounting tube to the front face Connect the sensor to the leads 1x male connection and 1x female connection Push the sensor into the mounting tube Secure the sensor...

Page 5: ...op 3 Screw the braided hose into the bottom of the mixer 4 Fit the mixer with the trim to the bench top 5 Refit the mounting plate and fixing but to the underside of the mixer Do the nut up finger tig...

Page 6: ...e cover plate to seal the unit to the wall Press the plate into position on the wall Apply thread sealant or thread tape to male thread and screw the outlet to the male thread 7 Turn on the water and...

Page 7: ...ed length Apply thread sealant or thread tape to the male thread of the spout nipple and screw the spout nipple into the female fitting in the wall 7 Run a thin bead of silicone sealant on the inside...

Page 8: ...able coming from the electronic sensor unit to the power source connector battery box or transformer 3 Connect the power source a For battery versions Install the battery box at the wall underneath th...

Page 9: ...to the two holes using two screws Important The mounting base should be installed so that the outside surface of the finished wall falls between the min and max lines marked on the base 6 Connect the...

Page 10: ...ed by the sensor even if the power source is disconnected To get back to the self adjustment mode use the Adj button E NTR A N C E TO TH E S E LF A DJ USTM E NT M O D E Check that no objects are in fr...

Page 11: ...battery Replace with 6 new batteries Sensor does not flash when user s hands are within the sensor s range Range is too short Increase the range using the remote control Range is too long Decrease the...

Page 12: ...ceeding recommended limits Improper manipulation tampering bad or lapsed maintenance Foreign bodies dirt or scale introduced by the water supply 2 2702 TF 0 0 0 B ROSMART TR ANSFO RM ER 2 270 5 S F 0...

Page 13: ...I CSEN 210509...

Reviews: