B AT T E R Y M O D E L S O N LY
When the battery weakens, the red indicator light will blink at a constant rate. The battery
must be replaced.
T O R E P L A C E T H E B AT T E R Y O N B AT T E R Y M O D E L S :
1. Carefully open the battery box.
2. Remove the old batteries.
3. Replace the used batteries with 6x AA batteries. (Lithium batteries are recommended).
4. Close the box.
C A R E A N D C L E A N I N G O F C H R O M E A N D S P E C I A L F I N I S H E S
The Brodware product you have purchased has been designed to provide many years of
dependable service. However, the finish, as on all plumbing products, requires care to be
taken to retard the wear that will eventually occur.
Whilst our Electoplate finishes are durable, we recommend cleaning with a non ammoniated
pure soap liquid to remove stains and water spots.
Rinse all traces of soap thoroughly. Wipe and buff gently with a soft cloth. Do not use abrasive
cleaners or sponges. We recommend the occasional application of a pure non abrasive polish
such as Mr Sheen™, which is helpful in preventing water spots on all finishes.
Unlacquered Polish Brass items, which normally tarnish because of the effects of water and
the atmosphere, will regain their shine by polishing with Brasso™ or Autosol™.
• Due to impurities in most water supplies, a regular cleaning of aerators is recommended.
• Ensure in line filter is cleaned or replaced on a regular basis.
A L L W O R K M U S T B E C A R R I E D O U T B Y A L I C E N S E D P L U M B E R
M A I N T E N A N C E
T R O U B L E S H O O T I N G
P R O B L E M
I N D I C AT O R
C A U S E
S O L U T I O N
N O W AT E R
F L O W
Sensor flashes
continuously when
user’s hands are
within the sensor’s
range.
Low battery
Replace with 6 new
batteries.
Sensor does not
flash when user’s
hands are within
the sensor’s range
Range is too short
Increase the range
using the remote
control
Range is too long
Decrease the range
using the remote
control
Battery is completely used up
Replace battery
Unit is in “Security Mode” *
See footnotes
Sensor is picking up reflections from
the washbasin or another object
Remove/eliminate
the cause.
Red light in the
sensor flashes
when user’s hands
are within range.
Connections between the
between the tap and solenoid are
disconnected
Connect the
solenoid to the tap.
Debris or scale in solenoid
Replace the
solenoid.
The water supply pressure is > 500kPa Reduce the water
supply pressure
Water supply pressure is <500kPa
yet the pressure in the taps body
is higher. This could be caused by
a sudden increase in the water
supply pressure that the back chock
prevents from dropping, even after
water supply pressure drops <500kPa.
Shut off water
supply and unscrew
the flexible pipes in
order to reduce the
pressure.
W AT E R
F L O W F R O M
S P O U T
D O E S
N O T
S T O P
Sensor flashes
when user’s hands
are within range.
Debris or scale in diaphragm
Clean the orifice
or replace the
diaphragm
Red light in the
sensor does not
flash when user’s
hands are within
the sensor’s range
Sensor is dirty or covered. **
Clean or eliminate
cause of
interference
Sensor is picking up reflections from
the washbasin or another object.
Decrease the range
or eliminate cause
of reflection
W AT E R
F L O W I S
D I M I N I S H E D
Filter or aerator is clogged
Remove, Clean,
Re-Install
* “Security Mode”: If the sensor is covered for more than 90 seconds the tap will automatically shut off water
flow. To return to normal operation remove obstruction.
** In this case, the water flow will stop anyway after 90 seconds because of the security time.
19
20
Summary of Contents for 2.2702.90