background image

B AT T E R Y   M O D E L S   O N LY

When the battery weakens, the red indicator light will blink at a constant rate. The battery  

must be replaced.

T O   R E P L A C E   T H E   B AT T E R Y   O N   B AT T E R Y   M O D E L S :

1.  Carefully open the battery box.
2.  Remove the old batteries.
3.  Replace the used batteries with 6x AA batteries. (Lithium batteries are recommended).
4.  Close the box.

C A R E   A N D   C L E A N I N G   O F   C H R O M E   A N D   S P E C I A L   F I N I S H E S

The Brodware product you have purchased has been designed to provide many years of 

dependable service. However, the finish, as on all plumbing products, requires care to be 

taken to retard the wear that will eventually occur.
Whilst our Electoplate finishes are durable, we recommend cleaning with a non ammoniated 

pure soap liquid to remove stains and water spots.
Rinse all traces of soap thoroughly. Wipe and buff gently with a soft cloth. Do not use abrasive 

cleaners or sponges. We recommend the occasional application of a pure non abrasive polish 

such as Mr Sheen™, which is helpful in preventing water spots on all finishes.
Unlacquered Polish Brass items, which normally tarnish because of the effects of water and 

the atmosphere, will regain their shine by polishing with Brasso™ or Autosol™. 
•  Due to impurities in most water supplies, a regular cleaning of aerators is recommended.
 •  Ensure in line filter is cleaned or replaced on a regular basis.

A L L   W O R K   M U S T   B E   C A R R I E D   O U T   B Y   A   L I C E N S E D   P L U M B E R

M A I N T E N A N C E

T R O U B L E S H O O T I N G

P R O B L E M

I N D I C AT O R

C A U S E

S O L U T I O N

N O  W AT E R   
F L O W

Sensor flashes 

continuously when 

user’s hands are 

within the sensor’s 

range.

Low battery

Replace with 6 new 

batteries.

Sensor does not 

flash when user’s 

hands are within 

the sensor’s range

Range is too short

Increase the range 

using the remote 

control

Range is too long

Decrease the range 

using the remote 

control

Battery is completely used up

Replace battery

Unit is in “Security Mode” *

See footnotes

Sensor is picking up reflections from 

the washbasin or another object

Remove/eliminate 

the cause.

Red light in the 

sensor flashes 

when user’s hands 

are within range.

Connections between the 

between the tap and solenoid are 

disconnected

Connect the 

solenoid to the tap.

Debris or scale in solenoid

Replace the 

solenoid.

The water supply pressure is > 500kPa Reduce the water 

supply pressure

Water supply pressure is <500kPa 

yet the pressure in the taps body 

is higher. This could be caused by 

a sudden increase in the water 

supply pressure that the back chock 

prevents from dropping, even after 

water supply pressure drops <500kPa.

Shut off water 

supply and unscrew 

the flexible pipes in 

order to reduce the 

pressure.

W AT E R 
F L O W   F R O M 
S P O U T 
D O E S   
N O T   
S T O P

Sensor flashes 

when user’s hands 

are within range.

Debris or scale in diaphragm

Clean the orifice 

or replace the 

diaphragm 

Red light in the 

sensor does not 

flash when user’s 

hands are within 

the sensor’s range

Sensor is dirty or covered. **

Clean or eliminate 

cause of 

interference

Sensor is picking up reflections from 

the washbasin or another object.

Decrease the range 

or eliminate cause 

of reflection

W AT E R 
F L O W  I S 
D I M I N I S H E D

Filter or aerator is clogged

Remove, Clean,  

Re-Install

* “Security Mode”: If the sensor is covered for more than 90 seconds the tap will automatically shut off water 

flow. To return to normal operation remove obstruction.
** In this case, the water flow will stop anyway after 90 seconds because of the security time.

19

20

Summary of Contents for 2.2702.90

Page 1: ...705 0 0 2 2705 02 2 2705 20 2 2705 22 2 2705 30 2 2705 70 2 2706 0 0 2 2706 02 2 2706 20 2 2706 22 2 2706 30 2 2706 70 2 2706 94 2 2702 90 2 2702 92 ELEC TRO N I C S EN SO R TAP I N STALL ATI O N MAI...

Page 2: ...ation of your sensor wall set After reading this manual if you still have any questions about the installation process or correct maintainance of the sensor wall set please call us on 61 1300 800 300...

Page 3: ...for gravity feed systems CO RREC T SOAP VI SCOS IT Y Ensure that the correct soap is selected for the Brosmart Sensor Soap Dispensers A soap with no grit and a viscosity of 100 3800cPs is to be used F...

Page 4: ...hrough from the rear of the Sensor Mounting tube to the front face Connect the sensor to the leads 1x male connection and 1x female connection Push the sensor into the mounting tube Secure the sensor...

Page 5: ...op 3 Screw the braided hose into the bottom of the mixer 4 Fit the mixer with the trim to the bench top 5 Refit the mounting plate and fixing but to the underside of the mixer Do the nut up finger tig...

Page 6: ...e cover plate to seal the unit to the wall Press the plate into position on the wall Apply thread sealant or thread tape to male thread and screw the outlet to the male thread 7 Turn on the water and...

Page 7: ...ed length Apply thread sealant or thread tape to the male thread of the spout nipple and screw the spout nipple into the female fitting in the wall 7 Run a thin bead of silicone sealant on the inside...

Page 8: ...able coming from the electronic sensor unit to the power source connector battery box or transformer 3 Connect the power source a For battery versions Install the battery box at the wall underneath th...

Page 9: ...to the two holes using two screws Important The mounting base should be installed so that the outside surface of the finished wall falls between the min and max lines marked on the base 6 Connect the...

Page 10: ...ed by the sensor even if the power source is disconnected To get back to the self adjustment mode use the Adj button E NTR A N C E TO TH E S E LF A DJ USTM E NT M O D E Check that no objects are in fr...

Page 11: ...battery Replace with 6 new batteries Sensor does not flash when user s hands are within the sensor s range Range is too short Increase the range using the remote control Range is too long Decrease the...

Page 12: ...ceeding recommended limits Improper manipulation tampering bad or lapsed maintenance Foreign bodies dirt or scale introduced by the water supply 2 2702 TF 0 0 0 B ROSMART TR ANSFO RM ER 2 270 5 S F 0...

Page 13: ...I CSEN 210509...