S T E P O N E :
1. Shut off water supply.
2. Ensure that the sensor is not installed within 300mm of any adjacent surface. Do not
install
the sensor facing a mirror or any other system operated by an infra-red sensor.
3. Install a ½” BSP male thread for the outlet in the required location/position. (Refer to the
dimensions on the drawing for correct positioning).
4. Below the male thread, a cut out of 50mm x 80mm is required in the wall to recess the
sensor and sensor mounting bracket. This is to be 110mm from centre of male thread, to
centre of the sensor eye.
5. Feed the leads from the transformer and from the solenoid from inside the wall cavity
through to the front of the recess for the sensor. Connect the sensor to the leads (1x male
connection, 1x female connection).
6. Run a thin bead of silicone sealant on the inside face of the cover plate to seal the unit to
the wall. Press the plate into position on the wall. Apply thread sealant or thread tape to
male thread, and screw the outlet to the male thread.
7. Turn on the water and power supply, and test for functionality. Adjustments to the sensor
range and run time are done by using the appropriate remote control (C27.02.RM sold
separately). If there are any set up queries, please refer to the troubleshooting section in
the back of this booklet.
Note: If there is not enough length in either lead, do not cut or make your own lead. Modifying
or making your own lead will void warranty. Brodware have extension leads to suit (part
numbers are in the spare parts list at rear of this booklet). Please contact your supplier to
place your order.
C O N T I N U E T O P A G E 1 3 F O R F O L LO W I N G I N S T R U C T I O N S T O C O M P L E T E T H E I N S TA L L AT I O N
O F Y O U R B R O D W A R E S E N S O R TA P
O U T L E T A N D S E N S O R I N S TA L L AT I O N G U I D E F O R
2 . 2 7 0 5 . 0 2 , 2 7 0 5 . 2 2 , 2 . 2 7 0 6 . 0 2 A N D 2 . 2 7 0 6 . 2 2
Note: Use 32mm conduit to conceal wiring