This command displays status information for the fans and power supplies, and temperature readings for various components in the
device. The power supplies are numbered in the display. Refer to
Displaying device status and temperature readings
on page 204 for
more information.
If a power supply has failed, the display indicates "Installed (Failed)" and identifies the slot in which the failed power supply is installed.
Setting the threshold for power supply monitoring
The
power-supply monitoring threshold
command monitors the power supply state, and indicates when a power supply will shut down
due to failure.
To set a threshold value for power supply monitoring, enter the following command.
device(config)#power-supply monitoring threshold 3
A Power Supply will be Shutdown if it fails 3 times within an Hour
The power supply will flap three times within an hour, after which the power supply will automatically shut down.
Syntax:
[no] power-supply monitoring
[
threshold
decimal
]
The
decimal
variable specifies the number of flaps within an hour after which a power supply will automatically shutdown. The threshold
range is from 0 through 32. The default value is 5. A value of 0 disables the power supply auto-shutdown on flapping.
NOTE
A threshold value of 0 will not automatically shutdown a power supply due to failures.
For Syslog messages, please refer to Appendix A, Using Syslog in the Brocade NetIron MLX Series
and Brocade NetIron Family
Configuration Guide
.
Clearing power supply failure timestamps
Use the
power-supply monitoring clear
command to clear all collected failure timestamps for a given power supply, or for all available
power supplies.
To clear all collected failure timestamps for a power supply, enter the following command.
device(config)# power-supply monitoring clear 1
This will clear all collected failure timestamps for the Power Supply # 1
Are you sure? (enter 'y' or 'n'): y
To clear all collected failure timestamps for all available power supplies, enter the following command.
device(config)# power-supply monitoring clear all
This will clear all collected failure timestamps for all available Power Supplies
Are you sure? (enter 'y' or 'n'): y
You are asked to verify this command by entering "yes" or "no".
Syntax:
power-supply monitoring clear
decimal
|
all
]
By default, no power-supply monitoring is configured.
The
decimal
variable specifies a power supply number, The
all
keyword clears all available power supplies.
Replacing a power supply
Brocade NetIron MLXe Series Hardware Installation Guide
250
53-1004203-04
Summary of Contents for NetIron MLXe Series
Page 8: ...Brocade NetIron MLXe Series Hardware Installation Guide 8 53 1004203 04...
Page 12: ...Brocade NetIron MLXe Series Hardware Installation Guide 12 53 1004203 04...
Page 20: ...Brocade NetIron MLXe Series Hardware Installation Guide 20 53 1004203 04...
Page 192: ...Brocade NetIron MLXe Series Hardware Installation Guide 192 53 1004203 04...
Page 270: ...Brocade NetIron MLXe Series Hardware Installation Guide 270 53 1004203 04...
Page 286: ...Brocade NetIron MLXe Series Hardware Installation Guide 286 53 1004203 04...
Page 292: ...Brocade NetIron MLXe Series Hardware Installation Guide 292 53 1004203 04...