state = 0 (FAN_STATE_LOW)
max_ts_shut_off_count = 1
shut_off_count = 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
The output displays the following information.
TABLE 43
Temperature threshold information for modules and fan speeds
This field...
Displays...
Thermal Sensor Control Block
(THERMAL_SENSOR_TEST_RULE_module)
The temperature threshold information for the various modules. The
module
parameter indicates the following:
•
MP - The active management module
•
STANDBY_MP - The standby management module
•
SNM - The switch fabric module
•
LP - An interface module
Fan Speed Low or Med or Med-Hi or Hi
The current setting of the low and high temperature thresholds for the low,
medium, medium-high, and high fan speeds.
NOTE
As indicated in
, the low fan speed for each module
does not have a default low temperature threshold value, nor
can you configure this value. The "-1" value that appears in the
Fan Speed Low field for each module is a Brocade internal
value only.
State = 0 (FAN_STATE_LOW)
For Brocade internal use only.
max_ts_shut_off_count
For Brocade internal use only.
shut_off_count = 0 0 0 0 0 0 0 0
For Brocade internal use only.
When syslog messages display a change in fan speed, you can identify which sensors triggered the change by checking
show chassis
and
show fan-threshold
command output and looking for sensors with temperatures near threshold boundaries. The following table lists
the associations between the
show chassis
,
show fan-threshold
, and
fan-threshold commands
.
NOTE
A "thermal block" refers to the group of high and low thresholds for all fan speed levels.
TABLE 44
Associations between show chassis, show fan threshold, and fan-threshold commands
show chassis
command output (sensors)
show fan-threshold
command output (thermal
block)
fan-threshold
command configuration
MP, SFM, and hSFM Modules
Active Management 1st reading
THERMAL_SENSOR_TEST_RULE_MP
fan-threshold mp
Active Management 2nd reading
THERMAL_SENSOR_TEST_RULE_MP_CPU
fan-threshold mp-cpu
Standby Management 1st reading
THERMAL_SENSOR_TEST_RULE_STANDBY
_MP
fan-threshold mp
Standby Management 2nd reading
THERMAL_SENSOR_TEST_RULE_STANDBY
_MP_CPU
fan-threshold mp-cpu
SFM FE1 reading
THERMAL_SENSOR_TEST_RULE_SNM
fan-threshold switch-fabric
SFM FE2 reading
THERMAL_SENSOR_TEST_RULE_SNM
fan-threshold switch-fabric
SFM FE3 reading
THERMAL_SENSOR_TEST_RULE_SNM
fan-threshold switch-fabric
hSFM FE1 reading
THERMAL_SENSOR_TEST_RULE_SNM_G2
fan-threshold switch-fabric-g2
hSFM FE2 reading
THERMAL_SENSOR_TEST_RULE_SNM_G2
fan-threshold switch-fabric-g2
hSFM FE3 reading
THERMAL_SENSOR_TEST_RULE_SNM_G2
fan-threshold switch-fabric-g2
Managing the cooling system
Brocade NetIron MLXe Series Hardware Installation Guide
53-1004203-04
215
Summary of Contents for NetIron MLXe Series
Page 8: ...Brocade NetIron MLXe Series Hardware Installation Guide 8 53 1004203 04...
Page 12: ...Brocade NetIron MLXe Series Hardware Installation Guide 12 53 1004203 04...
Page 20: ...Brocade NetIron MLXe Series Hardware Installation Guide 20 53 1004203 04...
Page 192: ...Brocade NetIron MLXe Series Hardware Installation Guide 192 53 1004203 04...
Page 270: ...Brocade NetIron MLXe Series Hardware Installation Guide 270 53 1004203 04...
Page 286: ...Brocade NetIron MLXe Series Hardware Installation Guide 286 53 1004203 04...
Page 292: ...Brocade NetIron MLXe Series Hardware Installation Guide 292 53 1004203 04...