SNM3: not present
LP1 Sensor1: 41.5C
LP1 Sensor2: 50.625C
LP4 Sensor1: 39.0C
LP4 Sensor2: 49.250C
LP4 Sensor3: UNUSED
LP4 Sensor4: 38.5C
LP4 Sensor5: 47.750C
LP4 Sensor6: UNUSED
Fans are in auto mode. Temperature Monitoring Poll Period is 60 seconds
The following table describes the
show chassis
command output.
TABLE 38
show chassis command output
Field
Description
Powers
Power
num
,
part num
The
Power
num
is the power supply number as positioned in the device.
The number of power supplies are as follows:
4-slot devices: 1 - 38-slot devices: 1 - 416-slot devices: 1 - 832-slot
devices: 1 - 8
The
part num
is the part number of the power supply purchased. This
applies to AC and DC power supplies.
Power
status
Indicates whether an AC or DC power supply is installed in the specified
power supply slot and the status of the power supply, which can be one of
the following:
•
Installed (Shutdown) - The power supply has shut down. A
power supply will shut down due to flapping, or if a shut down is
enabled manually using the power-off power-supply command.
Refer to
Enabling a power supply shutdown
on page 252.
•
Installed (OK) - The power supply is functioning properly and
supplying power to the device and installed modules.
•
Failed - The power supply is not functioning and is not
supplying power to the device and installed modules.
•
not present - There is no power supply installed in the slot.
•
Installed (Failed or Disconnected) - The power supply is not
functioning, or the power supply is not connected to the device
and installed modules.
Total power budget for device
The sum of all power (in watts), used by all power supplies currently
functioning in the device. Refer to
Hardware specifications for Brocade
Total power used by system core
The total power used by the management modules, switch fabric
modules, and fans. Each component consumes different amounts of
power.
Total power used by LPs
The total power used by the interface modules. Each module type
consumes different amounts of power.
Total power available
The total power budget for the device minus the total power used by the
system core and the installed interface modules.
Slot Power-On Priority
The configured power-on priority of each interface module.
Slot
num
Slot1 - Slot16
4-slot device: Slot1 - Slot48-slot device: Slot1 - Slot816-slot device:
Slot1 - Slot1632-slot device: Slot1 - Slot32
The
slot
num
is the device slot number.
The priority of each device slot as configured by the
lp-slot-priority
command. The priority can be 1 (low, default) - 8 (high). If the amount of
power supplied to the device falls below a minimum threshold, the device
slots with the lowest priority will likely lose power. For information about
using the
lp-slot-priority
command, refer to
Changing priority of slots for
Managing the device
Brocade NetIron MLXe Series Hardware Installation Guide
53-1004203-04
205
Summary of Contents for NetIron MLXe Series
Page 8: ...Brocade NetIron MLXe Series Hardware Installation Guide 8 53 1004203 04...
Page 12: ...Brocade NetIron MLXe Series Hardware Installation Guide 12 53 1004203 04...
Page 20: ...Brocade NetIron MLXe Series Hardware Installation Guide 20 53 1004203 04...
Page 192: ...Brocade NetIron MLXe Series Hardware Installation Guide 192 53 1004203 04...
Page 270: ...Brocade NetIron MLXe Series Hardware Installation Guide 270 53 1004203 04...
Page 286: ...Brocade NetIron MLXe Series Hardware Installation Guide 286 53 1004203 04...
Page 292: ...Brocade NetIron MLXe Series Hardware Installation Guide 292 53 1004203 04...