Traffic Manager XPP link monitoring
Traffic Manager (TM) XPP link status is checked during the line card boot up time. MP will attempt to recover TM XPP link errors by
executing resets and then keeping reset cards down that fail to recover after 3 resets.
Thus TM-XPP link is monitored at boot-up, and recovery action is performed. This check will be placed in periodic TM XPP link
monitoring to catch link issues at run time and perform appropriate recovery.
This feature is supported for the following line cards:
•
8x10GbE
•
20x10-GbE/1GBE (M) / FRU# 53-1003238-xx
•
20x10-GbE/1GbE (X2) / FRU# 53-1003275-xx
•
24x10GbE
•
4x40GbE
•
2x100GbE
Enabling TM-XPP link monitoring
To enable TM XPP link monitoring, enter the
sysmon tm nif-check
command as shown in the following section.
sysmon tm nif-check
Syntax
sysmon tm
nif-check
threshold
count polling period
[no] sysmon tm
nif-check
threshold
count polling period
Two recovery actions are possible which are listed below:
sysmon tmnif-check
action
disable-ports
NOTE
disable-ports
is default action.
[no] sysmon tmnif-check
actionreset-linecard
Parameters
count
Number of link error events occurred within this polling period.
polling period
Period for polling.
Traffic Manager XPP link monitoring
Brocade NetIron MLXe Series Hardware Installation Guide
53-1004203-04
227
Summary of Contents for NetIron MLXe Series
Page 8: ...Brocade NetIron MLXe Series Hardware Installation Guide 8 53 1004203 04...
Page 12: ...Brocade NetIron MLXe Series Hardware Installation Guide 12 53 1004203 04...
Page 20: ...Brocade NetIron MLXe Series Hardware Installation Guide 20 53 1004203 04...
Page 192: ...Brocade NetIron MLXe Series Hardware Installation Guide 192 53 1004203 04...
Page 270: ...Brocade NetIron MLXe Series Hardware Installation Guide 270 53 1004203 04...
Page 286: ...Brocade NetIron MLXe Series Hardware Installation Guide 286 53 1004203 04...
Page 292: ...Brocade NetIron MLXe Series Hardware Installation Guide 292 53 1004203 04...