To replace the air filter in the FastIron SX-1600, perform the following tasks.
1. Loosen the captive fasteners in the front of the filter retainer.
2. Pull the filter retainer away from the chassis as shown in the figure above.
There is a hook on the back of the retainer that is attached to the grab-strap. As you pull the retainer out, the filter is pulled along
with it.
3. Unhook the filter retainer from the air filter and discard the used filter.
4. Partially insert the replacement air filter (part number 11211-401) by sliding it along the metal guides.
The filter is marked with an arrow. The arrow indicates how the filter should be installed in regards to the direction of airflow in
the chassis. Since air is pulled through the chassis, the arrow must point up towards the fan tray.
5. Attach the hook on the back of the filter retainer to the filter grab-strap.
6. Push the filter retainer into the chassis and tighten the captive fasteners.
Mean time between failure
The table below lists the Mean Time Between Failure (MTBF) for the
FastIron X Series
chassis devices and modules. The MTBF is the
average estimated time, in units of hours, before a hardware failure may occur.
TABLE 28
MTBF for the
FastIron X Series
chassis and modules
Configuration or Module
Temperature
MTBF (hours)
FSX
FSX c fan backplane
40 ° C
1,003,172
FSX c fan bac one AC
power supply
40 ° C
269,386
FSX c fan bac one DC
power supply
40 ° C
272,432
AC power supply (non-POE supply)
40 ° C
368,282
AC POE power supply
40 ° C
139,000
DC power supply
40 ° C
374,000
FSX Management Modules
IPv6 Management Module with 256 MB
SDRAM and no optics
40 ° C
292,557
IPv6 Management Module with 256 MB
SDRAM and 12 optics
40 ° C
211,053
IPv6 Management Module with 512 MB
SDRAM and no optics
40 ° C
287,425
IPv6 Management Module with 512 MB
SDRAM and 12 optics
40 ° C
208,369
IPv4 Management Module with no optics
40 ° C
287,664
IPv4 Management Module with 12 optics
40 ° C
152,154
SX-FI-2XGMR-XL and the SX-FI-2XGMR-XL-
PREM6 management modules
40 ° C
506,155
FSX 800
FSX 800 + fan two switch fabric
modules
40 ° C
230,584
Mean time between failure
Brocade FastIron SX Series Chassis Hardware Installation Guide
Part Number: 53-1003613-04
155
Summary of Contents for FastIron SX
Page 10: ...Brocade FastIron SX Series Chassis Hardware Installation Guide 10 Part Number 53 1003613 04 ...
Page 12: ...Brocade FastIron SX Series Chassis Hardware Installation Guide 12 Part Number 53 1003613 04 ...
Page 46: ...Brocade FastIron SX Series Chassis Hardware Installation Guide 46 Part Number 53 1003613 04 ...
Page 80: ...Brocade FastIron SX Series Chassis Hardware Installation Guide 80 Part Number 53 1003613 04 ...
Page 118: ...Brocade FastIron SX Series Chassis Hardware Installation Guide 118 Part Number 53 1003613 04 ...
Page 158: ...Brocade FastIron SX Series Chassis Hardware Installation Guide 158 Part Number 53 1003613 04 ...
Page 164: ...Brocade FastIron SX Series Chassis Hardware Installation Guide 164 Part Number 53 1003613 04 ...
Page 172: ...Brocade FastIron SX Series Chassis Hardware Installation Guide 172 Part Number 53 1003613 04 ...