Manually switching over to the standby management module
This section describes how to manually switch the role of active management module from the currently active module to the standby
module.
NOTE
Hitless switchover is also supported. An enhancement to the manual switchover feature, a hitless switchover enables a
switchover of the active management module to standby module without interrupting switched traffic. For details, refer to the
FastIron Ethernet Switch Administration Guide
.
You can cause the system to switch over to the standby module (and thus make it the active module). To do so, enter the following
command.
device# switch-over-active-role
Once you enter this command, the system will prompt you as follows.
Are you sure? (enter ’y’ or ’n’): y
Running Config data has been changed. Do you want to continue
the switch-over without saving the running config? (enter ’y’ or ’n’): n
Please save the running config and try switch-over again
Syntax:
switch-over-active
role
Rebooting the active and standby management modules
You can use the
boot system
or
reload
commands to reboot the management modules, maintaining the currently configured active
management module (the management module to which the
set-active-mgmt
command applies).
For example, to reboot the active and standby management modules from the primary IronWare image in the management module’s
flash memory, enter the following command at the Privileged EXEC level.
device# boot system flash primary
Syntax:
boot system
{
bootup
|
flash primary
|
flash secondary
|
slot
|
tftp
ip-address
filename
[
fiber-port
]
The
flash primary
keyword specifies the primary IronWare image in the management module’s flash memory, while the
flash secondary
keyword specifies the secondary IronWare image in the flash memory.
The
tftp
keyword directs the switch to boot from an IronWare image on a TFTP server located at
ip-address
with the specified
filename
.
NOTE
To reboot the device from a TFTP server through a
fiber
connection, use the CLI command
boot system tftp
ip-address
filename
fiber-port
.
For example, to reboot the active and standby management modules, enter the following command at the Privileged EXEC level.
device# reload
Syntax:
reload
Monitoring management module redundancy
You can monitor the following aspects of management module redundancy:
•
The status of the management modules (if a module is the active or standby module)
Monitoring management module redundancy
Brocade FastIron SX Series Chassis Hardware Installation Guide
Part Number: 53-1003613-04
115
Summary of Contents for FastIron SX
Page 10: ...Brocade FastIron SX Series Chassis Hardware Installation Guide 10 Part Number 53 1003613 04 ...
Page 12: ...Brocade FastIron SX Series Chassis Hardware Installation Guide 12 Part Number 53 1003613 04 ...
Page 46: ...Brocade FastIron SX Series Chassis Hardware Installation Guide 46 Part Number 53 1003613 04 ...
Page 80: ...Brocade FastIron SX Series Chassis Hardware Installation Guide 80 Part Number 53 1003613 04 ...
Page 118: ...Brocade FastIron SX Series Chassis Hardware Installation Guide 118 Part Number 53 1003613 04 ...
Page 158: ...Brocade FastIron SX Series Chassis Hardware Installation Guide 158 Part Number 53 1003613 04 ...
Page 164: ...Brocade FastIron SX Series Chassis Hardware Installation Guide 164 Part Number 53 1003613 04 ...
Page 172: ...Brocade FastIron SX Series Chassis Hardware Installation Guide 172 Part Number 53 1003613 04 ...