Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide
page 50
Broadcom Confidential and Proprietary
Enable (1)
Enable hot plug power feature.
51
Pri. Port SMB Address (ASF/IPMI)
Configure
Description:
SMB address of the primary port on a device.
52
Sec. Port SMB Address (IPMI)
Configure
Description:
SMB address of the secondary port on a device (only valid for dual port devices).
53
Cable Sense
Configure
Description:
Enables a low power mode (IDDQ) of the chip which allows the presence of a cable to be
detected by the chip (valid for 5752M/5755M/5787M/5787FM devices). Once Cable Sense
is enabled GPIO3 will be an Energy Detect Output Pin and will be high if a cable (with a
signal present) is plugged into the RJ45 and low otherwise.
Disable (0)
Disable cable sense.
Enable (1)
Enable cable sense.
54
GPIO 0 Input/Output Config
Configure
Description:
Setting GPIO 0 input/output configuration (5714 LOM, 5715 LOM 5755M LOM only)
Input (0)
Config as input
Output HI (1)
Config as output HI
Output LO (2)
Config as output LOW
55
GPIO 2 Input/Output Config
Configure
Description:
Setting GPIO 2 input/output configuration (5714 LOM, 5715 LOM 5755M LOM only)
Input (0)
Config as input
Output HI (1)
Config as output HI
Output LO (2)
Config as output LOW
Example: (For Selfboot firmware).
0:>secfg
1. MAC Address.........: 001018000000
2. Device Id...........: 1693
3. Sub Vendor Id.......: 14E4
4. Sub Device Id.......: 1693
5. Wake on LAN.........: Disabled
6. WoL Speed Limit 10..: Disabled
7. LOM/NIC design......: NIC
8. Phy. Auto PowerDown.: Disabled
9. Reverse Nway........: Disabled
a. Disable PowerSaving.: Disabled
b. LED mode............: Phy1 Mode
c. Custom PCI power....: Yes (comsumed D0:100.D3:10 dissipated D0:100.D3:10)
d. Custom PCIE power...: Yes (3.3v, Sustained, D0, 1.2 Watt...)
e. Custom VPD-R Data...: Yes
g. Cable Sense.........: Disabled
h. MBA CFG Data........: Enabled