Broadcom NetXtreme Ethernet Adapter • Diagnostic User’s Guide
page 138
Broadcom Confidential and Proprietary
-h
Hide MBA Setup Prompt 0: Dis 1: En
-k
MBA Setup Hot Key 0: Ctrl-S 1: Ctrl-B
-m
MBA Boot Protocol 0: PXE 1: RPL 2: BOOTP 3: iSCSI
-v
Rd VPD Vendor Data V0
-b
MBA Bootstrap Type 0: Auto 1: BBS 2: Int18 3: Int19
-t
MBA Delay Time 0-15
-e
VLan 0: Dis 1:En
-i
VLAN
ID
-s
MBA Link Speed 0: Auto 1: 10HD 2: 10FD 3: 100HD 4: 100FD
10.219 eswitch
cmd:
eswitch
Description:
Configure Eswitch on the device that support eswitch, such as 5756.
Syntax:
eswtich
Options:
-d
Change the port to Docking mode
-l
Change the port to Laptop mode
-e
Enable E-switch, B57diag override the hardware manual switch.
-f
Forbid software E-Switch, but hardware eswitch works. Without this
option, PHY loopback test, external loopback test (pkttest -e), and
carrier test are performed on both laptop mode and docking mode.
With this option, above tests are performed on the default port.
-m
internal engineering manual switch and MAC test