Troubleshooting continued

Problem

Action

The unit will not turn on

Check the circuit breaker has not been tripped - if so reset it.
Reset the Cooler at the power supply.

The unit is blowing warm air

Check the water supply tap is turned on at the unit.
Check the pump has been selected on the wall control.

An error message is appearing 

Refer to the section on ‘Coded Messages’ and follow the checks.

on the Brivis Networker

Check the power point is plugged in and turned on to the Cooler.

The Brivis Networker display 

Check there is power to the power point with another appliance.

is blank

Check the circuit breaker has not been tripped - if so reset it.

The unit is not cooling very well

Check the water supply tap is turned on at the Cooler. Check the pump has 
been selected on the wall control.  Check sufficient door and/or windows have 
been opened.  Refer to Exhaust section.

There is no air coming 

Contact our service department to place a service call.

out of some vents

There is moisture on my tiles

Check  the  vents  are  directing  air  flow  across  the  ceiling  and  not  towards 
the floor.  If it is humid turn the pump off. Check sufficient door and/or windows 
have been opened.  Refer to Exhaust section.

The padlock is appearing 

This indicates that the child proof lock has been activated.

on the screen

Refer to the section on ‘Unlocking the Brivis Networker’.

For Your Records

Model Number:

Serial Number:

Install Date:

Installed by:

Installer Contact:

Service Records

To arrange a visit from one of our certified technicians please contact the Brivis Service department on 1300 BRIVIS

Service Provider:

Contact Number:

Service Year 2

Service Date:      /      /

Service Year 4

Service Date:      /      /

Service Year 6

Service Date:      /      /

Service Year 8

Service Date:      /      /

Service Year 10

Service Date:      /      /

CAAB022832O Cool Owners ISSUE D_021073O  24/08/15  10:21 AM  Page 16

Summary of Contents for AD56

Page 1: ...C O O L I N G Owner s Manual PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE USE Bonus offer when you register your product online brivis com au a company ...

Page 2: ...the PIN 9 To Lock the Brivis Networker To Unlock the Brivis Networker Zoning Dual Brivis Networker Operation 10 Batteries Operating your Programmable Wall Control 11 Automatic Pre Wet Operating Modes Auto Operation Getting Started Benefits of using coolers in Auto mode in preference to Manual mode 11 Manual Operation 12 Getting Started Fan Pump Fan only Pump only Using the Timer Setting the Timer ...

Page 3: ...y require the information for administration purposes While the supply of the information by you is voluntary if you cannot provide or do not wish to provide the information sought Brivis may not be able to provide the services you request If you have already provided information but have changed your mind and do not want the information used you may make application for access or amendment for th...

Page 4: ... be required To cool your whole house you need windows and or doors open throughout the house If you wish to concentrate your cooling to a select area simply concentrate all the required ventilation in the targeted area See following illustration Door 1 6m2 Hinged Window 0 3m2 Open Sliding Window 0 7m2 Table 1 Opening required for each model Brivis AD Series AD56 AD56D AD66 AD66D AD76 AD76D AD86 A...

Page 5: ...t has turned OFF at the end of use Brivis Advance Brivis Promina and Brivis Contour models have an additional pre programmed tank wash cycle flush This washes the tank with clean water at the end of use At the same time Brivis Contour models will also close the motorised ServoSeal damper which seals the ducting reducing drafts The ServoSeal and flush will occur approx 1 hour after the unit has bee...

Page 6: ... or Heater if fitted settings Variable Keys The keys numbered 1 5 vary their function depending on the program or mode displayed They will only have a function if text appears on the screen beside the key a black rectangular box Keys used for zoning function may also display an arrow Water Droplets The two alternating water droplets indicate that the cooler pump is turned on Fan Symbol When the fa...

Page 7: ...is Networker on using the ON OFF button Press the Auto key until Auto appears on the screen Rotate the round dial to set the comfort level you desire up to have a cooler comfort level and down to have a warmer comfort level Benefits of using Brivis coolers in Auto mode in preference to Manual mode Power and water consumption varies in relation to the chosen comfort level This comfort level cannot ...

Page 8: ...cooler pads Please Wait will scroll across the display It will take approximately 8 minutes for the unit to complete the pre wet before the fan will turn on Using the Timer When the Cooler is operating you can pre set a time for the Timer to turn the Cooler OFF Also when the Cooler is turned OFF you can select a time for the Timer to turn it ON automatically So if you are out for the day you can s...

Page 9: ... Press the PROG key and the display will flash OFF TIME and the word PROGRAM Rotate the round dial to set the OFF TIME ie the time you want the Cooler to turn OFF Press key 3 to activate the Timer Press the PROG key to exit and save your setting Checking your Timer Settings Once Timer settings are made you can review or cancel them in a number of ways The words On Time or Off Time will remain on t...

Page 10: ...ol displays the following messages For Australia Fan run hours indicate it is time for a service call For assistance call 1300 Brivis For New Zealand Fan run hours indicate it is time for a service call For assistance call 0800 427 484 The Spanner Icon will flash once every second on the Networker wall control display You may book a service call or clear the spanner icon notification by pressing K...

Page 11: ...er your current user PIN to lock the Brivis Networker The screen will now display System locked out If an incorrect number is entered press the auto key to clear all digits then re enter your PIN A flashing padlock icon indicates that the Brivis Networker is locked To Unlock the Brivis Networker Press the FUNCTION button followed immediately by Key 2 The screen will now display Enter Your PIN to u...

Page 12: ...her Brivis Networker In AUTO mode only the Master Brivis Networker will sense the comfort level within the house Batteries The Brivis Networker requires no batteries If the Brivis Networker has no screen check your 240 volt power supply at the Cooler or check the thermostat cable Note Only the Master Brivis Networker has the ability to set the clock time Look for the word clock beside Key 5 while ...

Page 13: ...tting Started Begin by pressing the On Off key to turn the Cooler on If the Auto light is illuminated the system is set for Automatic operation otherwise Press the mode key to cycle through the Cooler s operating modes until the Auto light is illuminated Push the UP and DOWN keys to select the comfort level you require The lower the number the cooler the setting the higher the number the warmer th...

Page 14: ... settings turn the wall control on make any adjustments if necessary then turn the wall control off and set the Timer When setting the timer to turn the cooler off have the cooler running at your desired settings and set the timer Setting the Timer Press the TIMER key to enter the timer setting mode The timer light will now be flashing and the screen will display a number Push the UP and DOWN keys...

Page 15: ...p Assembly Pads and Water Distribution Ember protective guards for AD BAL units Please note that to maintain your warranty the above servicing needs to be conducted by an authorised person trained in the service of Brivis Coolers Please contact our Brivis Service Department for an authorised Brivis Service Technician Note Service maintenance is not covered under warranty and is a chargeable servic...

Page 16: ...on the wall control Check sufficient door and or windows have been opened Refer to Exhaust section There is no air coming Contact our service department to place a service call out of some vents There is moisture on my tiles Check the vents are directing air flow across the ceiling and not towards the floor If it is humid turn the pump off Check sufficient door and or windows have been opened Refe...

Page 17: ...cords on page 14 before sending Tear here Fold Seal Tear here Site Details Name __________________________________________________________________________________________ Postal Address __________________________________________________________________________________ Site Address if different to above __________________________________________________________________ _____________________________...

Page 18: ...___________ What type of home do you live in Single Storey q Double Storey q Split Level q What type of roof do your have Tile q Metal q Other ______________ What type of wall control do you have Manual q Programmable q Brivis Networker q Delivery Address 61 Malcolm Rd BRAESIDE VIC 3195 Brivis Climate Systems Reply Paid 85321 BRAESIDE VIC 3195 ...

Page 19: ...with clean water Q I own a Brivis Advance or Brivis Promina cooler Why does the unit dump water periodically during operation A Brivis Advance and Brivis Promina coolers use the Running Refresh method for tank water quality control This Running Refresh ensures that the salt or sediments accumulating in the cooler do not exceed an acceptable level by periodically flushing the tank while the cooler ...

Page 20: ...efit from clean ducts Clean the Cooler fan and assembly Clean the Supply air diffusers Q Can I run heating through the same ductwork as my evaporative cooler A No the differing technology between ducted heating and evaporative cooling doesn t allow the units to share the same ductwork Also evaporative cooling requires larger ductwork for airflow Q How far should my cooler be away from sanitary ven...

Page 21: ...he Proof of Purchase or the holder of a property transfer document where the Product is included as part of the chattels 10 Product means the equipment purchased by the Purchaser and described in Section 2 of this document 11 Proof of Purchase means a Tax Invoice or Receipt in respect of the Product In the case of new constructions a Certificate of Occupancy or a Certificate of Compliance that det...

Page 22: ...oltage fluctuations over voltage transients or electromagnetic interference inadequate or faulty gas drainage services or water services including water pressure and non potable water d damage problems or failure caused by acts of God fire wind lightning flood storm vandalism earthquake war civil insurrection misuse abuse negligence accident pests animals pets vermin insects spiders or entry of fo...

Page 23: ... theusage environment including but not limited to a regularly cleaning the air filter s and replacing them where necessary b replacing expired batteries or other consumables as required c ensuring that the condensate drain is kept clean and clear of obstructions d ensuring that outdoor units have unrestricted airflow and adequate clearances e ensuring that additional corrosion protection is appli...

Page 24: ...670 Fax 64 04 920 1681 www warmair co nz email sales warmair co nz Brivis South Africa Distributor Lorenz and Associates Northlands Deco Park Cnr Witkoppen and Newmarket Roads North Riding Johannesburg South Africa 2194 0861 BRIVIS 0861 274 847 Ph 27 011 704 6112 Fax 27 011 704 0022 www brivis co za email info brivis co za Part Number B022832O September 2015 Brivis Pty Ltd ABN 64 096 079 088 Brivi...

Reviews: