Self Regulating Heating Cable
© BriskHeat
®
Corporation. All rights reserved.
3
IMPORTANT SAFETY INSTRUCTIONS
SAFETY ALERT SYMBOL
The symbol above is used to call your attention to instructions concerning
your personal safety. It points out important safety precautions. It means
“ATTENTION! Become Alert! Your Personal Safety is involved!”
Read
the message that follows and be alert to the possibility of personal injury
or death.
WARNING
CAUTION
A person who has not read and understood all operating Instructions is
not qualified to operate this product.
DANGER
Do not immerse heater in liquid.
Keep volatile or combustible material away from heater when in
use.
Use heater only in approved locations.
Keep sharp metal objects away from heater.
Failure to observe these warnings may result in electric shock, risk of
fire, and personal injury.
DANGER
Never handle the heater while it is in operation; always disconnect
the heater from the power source and allow to cool prior to
handling.
Inspect heater and connection kits before use.
If spillage of foreign matter onto heater occurs, disconnect from
power source and clean after heater is allowed to cool.
Never operate a heater without an appropriate heat sink (device
being heated is considered a heat sink).
Do not operate heater above rated temperature value.
Fasten heater to device using approved methods only.
Do not repair damaged or faulty heaters.
Do not crush or apply severe physical stress on heater or cord
assembly.
Disconnect heater when not in use.
Failure to observe these warnings may result in personal injury or
damage to the product and/or property.
CAUTION
Immediate hazards which
WILL
result in severe personal injury or death.
Hazards or unsafe practices that
COULD
result in severe personal injury
or death.
Hazards or unsafe practices that
COULD
result in minor personal injury or
property damage.
End User Must Comply to the Following:
Only qualified personnel are allowed to connect the electrical
wiring.
De-energize all power circuits before installation or servicing.
Keep ends of heating devices and kit components dry before and
during installation.
The conductive layer of this heating device must be connected to a
suitable grounding/earthing terminal.
Installation in accordance with the Canadian Electrical Code Part I
(Canada) or the National Electric Code (USA) as applicable.
All electrical wiring must follow local electrical codes.
The person who performs the final installation / wiring must be
qualified for this work.
The end-user is responsible for providing a suitable disconnecting
device.
The end-user is responsible for providing suitable electrical
protection device. It is highly recommended that a ground fault
circuit breaker be used.
Failure to observe these warnings could result in severe personal injury
or death.
WARNING
DANGER
Self Regulating Heating Cable
© BriskHeat
®
Corporation. All rights reserved.
4
SLCBL
SLMCBL
SLHCBL
SLMCAB
SLHCAB
OUTER JACKET
P = Thermoplastic; F = Fluoropolymer
TINNED VOLTAGE
120=110-COPPER BRAID
Supply 120VAC; 240=220-277 VAC
OUTPUT POWER AT 10°C
For SLHCAB: 5=5For SLCBL:
3=3W/ft; 5=5W/ft; 8=8W/ft; 10=10W/ft; 12=12W/ft;
For SLMCBL: 5=5W/ft; 10=10W/ft; 15=15W/ft; 20=20W/ft;
For SLHCBL: 5=5W/ft; 10=10W/ft; 15=15W/ft; 20=20W/ft;
For SLCAB: 3=3W/ft; 5=5W/ft; 8=8W/ft; 10=10W/ft;
For SLMCAB: 5=5W/ft; 10=10W/ft; 15=15W/ft;
W/ft; 10=10W/ft; 15=15W/ft; 20=20W/ft; 25=25W/ft; 30=30W/ft;
PART INTENDED USE
The following standard must apply for installaions in the USA.
IEEE 515.1 Installation Type A, Insulated Surfaces (including pipes)
IEEE 515.1 Installation Type B, Roof and Gutter De-Icing
IEEE 515.1 Installation Type C, Embedded Snow Melting
PART NUMBER MATRIX
X YYY B Z
SLCAB