Renovent Sky 200 Rev. C
21
Chapter 6 Display
6.4.3 Installer menu
From the main menu, turn the right-hand setting knob
to select the
“Installer”
PHQXDQGFRQ¿UPWKHVHOHFWLRQ
by pressing the right-hand setting knob.
If several appliances are connected, a selection from
the appliances can be made in this menu; if only a Sky
appliance is connected, then select HRV appliance:
-
HRU-appliance
10.57
Installer
01.03.16
HRU-appliance
10.56
Main menu
01.03.16
Device information
Basic settings
Installer
10.54
HRU-Ventilation
23/11/15
0 8 :0 0 17:0 0
-
Î
Ð
10.56
Installer HRU
01.03.16
Device settings
Factory settings
Î
10.56
01.03.16
Installer HRU
Device settings
Please wait
loading data
Ð
10.56
Installer HRU
01.03.16
Device settings
Factory setting
Î
ca.
10 sec
10.56
01.03.16
Installer HRU
Device settings
Airflow-mode 0
Airflow-mode 1
Airflow-mode 2
Airflow-mode 3
Bypass temperature
Bypass hysteresis
Operation bypass valve
CH + HRU
Imbalance allowed
Additional heater
Temperature postheater
V1 Selection input 1
V1 Min. voltage
V1 Max voltage
CN1 Condition input 1
CN1 Supply fan mode
CN1 Extract fan mode
V2 Selection input 2
V2 Min. Voltage
V2 Max. Voltage
CN2 Condition input 2
CN2 Supply fan mode
CN2 Extract fan mode
GEO Heat exchanger
GEO Minimum temperature
GEO Maximum temperature
RH Sensor
Sebsitivity RH-sensor
eBus CO2 sensors
Min. PPM ebus CO2-Sensor 1
Max.PPM ebus CO2-Sensor 1
Min. PPM ebus CO2-Sensor 2
Max.PPM ebus CO2-Sensor 2
Min. PPM ebus CO2-Sensor 3
Max.PPM ebus CO2-Sensor 3
Min. PPM ebus CO2-Sensor 4
Max.PPM ebus CO2-Sensor 4
Offset flow
Default position switch
Fixed imbalance
From this menu can be chosen from:
A
Device settings
%
Factory setting
A
Device settings
Selecting parameter takes you to the
overview of all step numbers of the
appliance as described in chapter
12. In this menu you can view these
values and, if necessary, modify
them.
Incorrect settings may se-
riously affect the proper
performance of the appli-
ance!
%
Factory setting
Selecting factory setting will restore
all step numbers to the original fac-
tory setting. All fault messages will
be deleted as well.
Î
A
B
Ð
10.56
01.03.16
Installer HRU
Reset to factory settings?
No
Yes
Ð
10.56
01.03.16
Installer HRU
Factory setting
Settings are reset to
factory setting
Ð
10.59
01.03.16
Airflow - mode 0
50m³/h
Standard: 50 m³/h
Range: 0 or 50 m³/h
Summary of Contents for Renovent Sky 200
Page 1: ...Renovent Sky 200 Plus WWW BRINKAIRFORLIFE NL 614485 C INSTALLATION INSTRUCTIONS English ...
Page 2: ......
Page 17: ...Renovent Sky 200 Rev C 13 Chapter 5 Installation A A X A 1 2 3 4 A t 60 mm t A ...
Page 18: ...14 Renovent Sky 200 Rev C Chapter 5 Installation A A X A 1 2 3 4 A t 60 mm t A ...
Page 32: ...28 Renovent Sky 200 Rev C Chapter 8 Maintenance 12 13 14 15 16 4x 3x 17 ...
Page 47: ......