12
Renovent Sky 200 Rev. C
7KH 5HQRYHQW 6N\ PXVW DOZD\V EH ¿WWHG ZLWK D FRQGHQVDWH
discharge.
The condensate must be discharged through a drainpipe
The condensate discharge connection with 3/4” mail thread
(supplied with the appliance) must be screwed into the
appliance’s condensate bin by the installer.
Important:
Always install a detachable coupler in the
condensate discharge line as closely as possible
WR WKH DSSOLDQFH RWKHUZLVH WKH FRQGHQVDWH ELQ
cannot be removed from the appliance for service
purposes!
The condensate discharge line can be mounted to it, preferably
glued, if necessary using a square bend. The installer can
glue the condensate discharge to the appliance in the desired
position. The drain must discharge under the water level in the
U-trap. Use a condensate discharge line with a diameter of 32
mm.
3DUWLFXODUO\IRUFHLOLQJPRXQWLQJPDNHVXUHWKHFRQGHQVDWH
discharge is below the level of the condensate bin in the
Renovent Sky!
Before connecting the condensate discharge to the appliance,
pour water into the U-trap to create an air trap.
Detachable coupler
0D[1P
3/4”
Detachable coupler
5.3
Connecting the condensate discharge
Chapter 5 Installation