4.1 Description
4.3 Frost
protection
5HQRYHQW6N\3OXVYHUVLRQ
The appliance comes plug and play and operates fully
automatically. The extracted indoor air heats up the fresh,
clean outdoor air. That saves energy and fresh air is sent to the
required rooms.
The control system has four ventilation modes.
7KH DLU ÀRZ UDWH FDQ EH DGMXVWHG SHU YHQWLODWLRQ PRGH 7KH
FRQVWDQWYROXPHFRQWUROV\VWHPHQVXUHVWKDWWKHDLUÀRZUDWH
of the supply and extract fans is realised independent of the
duct pressure.
The standard bypass valve makes it possible to supply fresh
outside air that is not heated by the heat exchanger. Particularly
during summer nights it is desirable to supply cooler outside
air. Then the hot air in the dwelling is replaced by cooler outside
air in so far as possible.
The bypass valve opens and closes automatically when a
QXPEHURIFRQGLWLRQVDUHVDWLV¿HGUHIHUWRWKHWDEOHEHORZIRU
bypass conditions).
7KH RSHUDWLRQ RI WKH E\SDVV YDOYH FDQ EH DGMXVWHG LQ VWHS
number 5, step number 6 and step number 7 in the settings
menu (see chapter 12).
%\SDVV
valve
open
- The outdoor temperature is higher than 7°C
and
- the outdoor temperature is lower than the indoor temperature in the dwelling
and
- the temperature in the dwelling is higher than the temperature set at step no. 5 in the settings menu
(set a standard at 22°C).
%\SDVV
valve
closed
- The outdoor temperature is lower than 7°C
or
- the outdoor temperature is higher than de indoor temperature in the dwelling
or
- the temperature from the dwelling is lower than the temperature set at step no. 5 in the settings menu minus the
set temperature by the hysteresis (step no. 6), this temperature is factory 20 °C (22,0 °C minus 2,0 °C).
To prevent freezing of the heat exchanger at extremely low
outdoor temperatures, the Renovent Sky features intelligent
frost control. Temperature sensors measure the temperatures
across the heat exchanger and, if necessary, the preheater is
switched on. That guarantees a proper ventilation balance,
also at very low outdoor temperatures. If, with switched on
preheater(s), the exchanger temperature still starts to drop
below zero, stepless unbalance is created in the appliance.
The Renovent Sky is also available as Plus version. This
version is equipped with a different control board with 2
additional connectors (X14 & X15) with more connection
options for various applications.
Only the Plus is equipped with a 9-pole connector (connected
to X15 on control board) that is accessible from the outside of
the appliance.
If a postheater or extra preheater is connected to connector
X14 (accessible after opening the front panel ) the installer
must feed the connected 230 Volt cable to outside the appliance
through a strain reliever. For this strain reliever (not supplied
with the appliance) a plug must be removed from the position
where this strain relieve must be placed.
See §9 for more information on the connection possibilities of
connectors X14 and X15.
8
Renovent Sky 200 Rev. C
%\SDVVFRQGLWLRQV
Chapter 4 Operation
9-pole
connector
Hole for gland to be mounted by installer (for sleeve
cable postheater/ extra preheater).
Summary of Contents for Renovent Sky 200
Page 1: ...Renovent Sky 200 Plus WWW BRINKAIRFORLIFE NL 614485 C INSTALLATION INSTRUCTIONS English ...
Page 2: ......
Page 17: ...Renovent Sky 200 Rev C 13 Chapter 5 Installation A A X A 1 2 3 4 A t 60 mm t A ...
Page 18: ...14 Renovent Sky 200 Rev C Chapter 5 Installation A A X A 1 2 3 4 A t 60 mm t A ...
Page 32: ...28 Renovent Sky 200 Rev C Chapter 8 Maintenance 12 13 14 15 16 4x 3x 17 ...
Page 47: ......