42
Renovent Sky 200 Rev. C
Chapter 13 ErP-value
3URGXFWGDWDVKHHWFRQIRUP(FRGHVLJQ(8QU$QQH[,9
Supplier:
%ULQN&OLPDWH6\VWHPV%9
Model:
5HQRYHQW6N\3OXV
Climate zone
Type of control
SEC-Value
in kWh/m²/a
Energyclass
(SEC)
The annual electricity
consumption
(AEC) in kWh
The annual heating saved
(AHS)
in kWh
Average
“Brink Air control”
-36,06
A
354
4335
Central demand control
-38,07
A
322
4389
Local demand control
-41,59
A
257
4490
Cold
“Brink Air control”
-78,00
A+
891
6617
Central demand control
-80,53
A+
859
6698
Local demand control
-85,09
A+
794
6862
Warm
“Brink Air control”
-12,03
E
309
2282
Central demand control
-13,75
E
277
2310
Local demand control
-16,68
E
212
2366
Type of ventilation unit:
Ventilation unit with heat recovery
Fan:
Variable speed EC fan
Type of heat exchanger:
5HFXSHUDWLYHSODVWLFFURVVFRXQWHUÀRZKHDWH[FKDQJHU
7KHUPDOHI¿FLHQF\
83%
0D[LPXPÀRZUDWH
200 m³/h
Electric power input:
114 W
Sound power level Lwa:
49dB(A)
5HIHUHQFHÀRZUDWH
140 m³/h
Reference pressure difference:
50Pa
6SHFL¿F3RZHU,QSXW6(/
0,26 W/m³/h
Control factor:
1,0 in combination with manual switch
0,95 in combination with Air control
0,85 in combination with
central demand control with1 sensor
0,65 in combination with local demand control with at least two or more sensors
and with at least a two-zone control
Leakage*:
Internal
0,8%
External
3,0%
Filterwarning:
On the Manual switch / Air control.
Attention!
)RURSWLPDOHQHUJ\HI¿FLHQF\DQGDSURSHURSHUDWLRQDUHJXODU¿OWHULQVSHFWLRQ
cleaning or replacement is necessary.
Internet address for Assembly instructions:
http://www.brinkclimatesystems.nl/installateurs/kenniscentrum/Documentatie.aspx
Bypass:
Yes; 100% Bypass
* Measurements executed by TZWL according to the EN 13141-7 standard (TZWL-report M.84.03.215.AD, June 2016)
&ODVVL¿FDWLRQIURP-DQXDU\
SEC Class („Average climate“)
SEC in kWh/m²/a
A+
0RVWHI¿FLHQW
SEC < -42
A
6(&
B
6(&
C
6(&
D
6(&
E
6(&
Summary of Contents for Renovent Sky 200
Page 1: ...Renovent Sky 200 Plus WWW BRINKAIRFORLIFE NL 614485 C INSTALLATION INSTRUCTIONS English ...
Page 2: ......
Page 17: ...Renovent Sky 200 Rev C 13 Chapter 5 Installation A A X A 1 2 3 4 A t 60 mm t A ...
Page 18: ...14 Renovent Sky 200 Rev C Chapter 5 Installation A A X A 1 2 3 4 A t 60 mm t A ...
Page 32: ...28 Renovent Sky 200 Rev C Chapter 8 Maintenance 12 13 14 15 16 4x 3x 17 ...
Page 47: ......