30
BRIGGSandSTRATTON.COM
3. Measure for 120 VAC ouput (
C
, Figure 62).
4. Disconnect the main winding connector and measure
resistance across the windings (
D
, Figure 63).
5. Then measure resistance across sub-windings (
E
, Figure 64).
•
If resistance is 1.35 - 1.75 Ω the windings are good.
•
If resistance is not to specifications, check wire
connections or repair/replace wires, then retest.
•
If resistance is still not to specifications, proceed to
Step 5.
•
If resistance is 0.15 - 0.30 Ω the windings are good.
•
If resistance is not to specifications, check wire
connections, or repair/replace wires, then retest.
•
If resistance is still not to specifications, replace the
stator winding.
Figure 62
C
Figure 63
D
Figure 64
E
No DC Output
1. Press the DC circuit breaker (
A
, Figure 65) and retest. If
still no DC output, proceed to Step 2.
Figure 65
A
•
If voltage is not measured, check for loose wiring.
• Repair/replace
as
necessary.
Not