Engine Will Not Start
The Engine Cranks But Has No Spark
If the engine cranks but has no spark, it could be the micro
switch (
A
, Figure 43).
Test the continuity of the microswitch as follows:
1. Remove
the
control
panel.
2. Disconnect the 10-pin connector (Figure 44) that is
connected to the ignition module (module with three LED
lights).
Figure 46
Figure 43
A
Figure 45
A
Spark Plug
See
Engine Maintenance
.
3. Turn the microswitch on and test between the terminal
(
A
, Figure 45) and ground.
4. If there is no continuity at the 10-pin connector, test
at the switch. If the microswitch is pressed down
(Figure 46) there should be continuity. If not, replace the
switch.
Figure 44
•
When the switch is in the ON position, no continuity
should be measured.
•
When the switch is in the OFF position, continuity
should be measured.