2. Remove control panel from enclosure and, without
disconnecting wiring, set control panel aside (
D
, Figure 23).
3. Remove inverter from enclosure (
E
) and, without
disconnecting wiring, set inverter assembly aside.
Figure 23
E
D
4. Close vent on fuel cap. Carefully spread ends of
generator housing to remove fuel tank (Figure 24) from
unit. Set fuel tank aside.
Figure 24
5. Locate fuel valve (
F
, Figure 25) inside of the generator
enclosure.
6. Remove
hoses
(
G
) and loosen screw (
H
) to remove the
fuel valve.
7. Install a new fuel valve using the above steps in reverse
order.
Fuel Filter
The fuel filter is located inside the fuel tank (See Figure 18)
and can be accessed by removing fuel hose. If fuel is not
flowing properly, remove the filter and clean it with carb
cleaner or other appropriate cleaner.
If fuel will not flow after cleaning, replace the filter.