16
NOTE:
-When WI-FI setup is completed, your PC or mobile will resume your default WI-FI connection.
-During AP mode, you can press and hold the
[ SENSO
R / WI-FI ]
key for 6 seconds to stop AP
mode and the console will restore your previous setting.
TIME ZONE
To automatically set the time display to your time-zone, change the time zone in SETUP page of
previous section from '0:00' (default) to your time zone (e.g.+1:00 for Germany).
TIME SERVER CONNECTION STATUS
After the console has connected to the internet, it will
attempt to connect to the internet time server to obtain
the UTC time. Once the connection succeeds and the
console's time has been updated, the “
” icon will
appear on the LCD.
ADVANCE SETTING IN WEB INTERFACE
Press
"ADVANCED"
key at the top of web interface to enter the advance setting page, this page
allow you to set and view the calibration data of the console, as well as update the firmware
version on PC web browser.
Upload
Browse
Firmware version: 1.00
-560~ 560hpa / -16.54 ~ 16.54inHg / -420 ~ 420mmH
g
Setting Range:
Temperature
o
C
Outdoor
Indoor
CH 1
CH 2
CH 3
CH 4
CH 5
CH 6
CH 7
Humidity %
Relative Pressure Offset:
Absolute Pressure Offset:
hpa
Range: -20 ~ 20
(Default: 0.0)
Current offset: 10
Current offset: -9
Current offset: -5
Current offset: 2
Current offset: -2
Current offset: 3
Current offset: -2
Current offset: 1.2
Current offset: -5
Current offset: -0.2
Current offset: -3
Current offset: -20.1
Current offset: -10
Current offset: 11.5
Current offset: -3
Current offset: -3
(Default: 0)
Current offset: 10
(Default: 0)
Current offset: 0.2
Current offset: -5
Current offset: 1
Pressure
Range: -20.0 ~ 20.
0
o
C
-36.0 ~ 36.
0
o
F (Default: 0.0)
*UV gain:
Range: 0.01 ~ 10(Default: 1.00)
Current gain: 1.1
*Light gain:
Range: 0.01 ~ 10(Default: 1.00)
Current gain: 1.1
* Depends on the model
*Wind speed gain:
*Wind direction:
*Rain gain:
Range: 0.5 ~ 1.5(Default: 1.00)
Range: -10 ~ 10(Default: 0
o
)
Range: 0.5 ~ 1.5(Default: 1.00)
Current gain: 0.85
Current offset: 2
o
Current gain: 0.75
SETUP
ADVANCED
Select setting unit
Press "SETUP" icon to
Setup page
Outdoor and Ch 1~7
temperature calibration
section
Pressure calibration
section
Current firmware
version
The firmware update
function only available
in PC web browser
ADVANCED page
Select setting unit
The rain, wind speed, UV and Light
calibration use gain method. The
wind direction is +/- 10 offset.
Outdoor and Ch 1~7 humidity
calibration section
Current offset value is the value
that you set before to offset the
pressure reading.