background image

Instructions for use halogen floodlight with motion sensor
Model: RP 150 W / PL 150 P and RP 500 W / PL 500 P

Warning

: Ensure electricity is switched off at mains before installation, replacement of bulb or servicing.

Please read through all following instructions before attempting to install the unit. 

The Brennenstuhl halogen lamps  must be

connected by an approved specialist in accordance with VDE 0100 using a three-core conductor. The earth wire (green-
yellow) must absolutely be connected to the medium terminal. Please refer to 

mark in the connection box.

Important

: This product has been designed and manufactured to automatically control floodlight at outdoor area once the integral

infrared detector has sensed a human presence. This is not intended for any other application or use.

I) Installation and standard wiring instructions

1. Not mounting at the vibrational surface.
2. Mounting position: The floodlight should, ideally, be fixed with the wall fixing bracket as per Fig. 1.

Minimum distance from 
illuminated area 1 metre.

3. Mark the hole positions for fixing bracket onto the wall. Drill and plug the wall at the marked positions. Screw the fixing bracket to

the wall with suitable screw (not supplied). See Fig. 2.

4. Unscrew the junction box cover and remove diffuser and rubber seal.
5. Put your 3-core mains cable into the junction box through the plastic stud and rubber gasket. 
6. Connect the 3 wires as per Fig. 3.
7. Replace the junction cover. Take care not to lose the rubber gasket on the cover.
8. Undo Screw/s on the front glass cover and hinge open. Insert bulb into spring loaded holders. Do not touch the bulb with bare

hand. Close glass cover and tighten. Ensure that all seals and grommets are secure see Fig. 4.

9. Mount the unit to the wall fixing bracket with replacing the two bolts. Adjust the floodlight to desired position and tighten the two

bolts (refering to the mounting instructions, Fig. 7).

Note: 

In order to increase the service life of the halogen lamp, only use/mount the spotlight horizontally (+/– 15°).

II) Operating instructions of movement detector

1. You can see the detection area of movement detector(PIR) as per Fig. 5. You can select the scanning field of PIR by adjusting the

rotating adjuster and moving the PIR sensor as show in Fig. 6.

2. You can select the relay time (from 15 ±5 seconds to 3 ±1 minutes) and Lux level (from daylight to night) by adjusting TIME and

LUX knobs see Fig. 6.

3. The (

)

position indicates that the PIR can works during daylight and night, the ( ) position indicates that the PIR only work at

night, and you can select the desired Lux control level by yourself.

4. Must loose the cope stud before rotating PIR Sensor.
5. Adjusting the detection area by rotating the PIR Sensor and floodlight.
6. Adjusting the duration time: Turning the TIME KNOB from – to + will increase the duration time (refering to the Fig. 6).
7. Adjusting the Lux control level: Turning the LUX KNOB clockwise to set a time between day and night to switch on the light.
8. Adjusting the sensitivity: Turning the SENS KNOB from – to + will increase the sensitivity (refering to the Fig. 6).
9. Walk-Test: Determining the detection area by Walk-Test. Once the PIR sensor receives a valid trigger signal (such as movement of

a human body) within its detection area, the floodlight will be turned on for the preset period of time. Please placing the LUX con-
trol to »Day« position and the TIME control to minimum (-) during Walk-Test. 

Important: Never attempt to remove the lens cover, as this will damage the PIR and render all gurantee invalid.

Warning: The floodlight must be earthed. Before touching the floodlight, please switch off and allow it to cool. 
A damaged glass lens has to be replaced by an original one of
Brennenstuhl before further operation of the halogen spotlight.

Please note the warning mark (label) on the floodlight.

Technical Date
Model:

RP 150 W / PL 150 P and RP 500 W / PL 500 P

Voltage:

220 - 240 V~, 50 Hz

Bulb:

Max. 150 Watt , R7S 78 mm tungsten halogen lamp
(suitable for RP 150 W + PL 150 P)
Max. 500 Watt , R7S 78 mm tungsten halogen lamp
(suitable for RP 500 W + PL 500 P)

Waterproof:

IP 44

Tempered Glass:

178 mm x 140 mm x 5 mm (RP 500 W + PL 500 P)

(L x W x T)

133 mm x 93 mm x 4 mm (RP 150 W + PL 150 P)

Unit Dimension:

180 mm x 145 mm x 235 mm (RP 500 W + PL 500 P)

(L x W x H)

140 mm x 115 mm x 200 mm (RP 150 W + PL 150 P)

Detection area:

Up to 12 m

Detection angle:

180°

Switch-on period: From 15 (±5) seconds to 3 (±1) minutes

4

1 m

109001 Halo RP 150 u. 500 W m. Bewegungsmelder  19.04.2006  8:13 Uhr  Seite 4  User: Steffen 

Summary of Contents for RP 150 W/PL 150 P

Page 1: ...oiettore alogeno con sensore di movimento Haszn lati utas t sa Mozg s rz kelo vel ell tott halog n f nysz r N vod k pouz it Halogenov ho z r ic e s hl sic em pohybu Navodila za uporabo Halogenskega z...

Page 2: ......

Page 3: ...zum Einstellen des Bewegungsmelders 1 Abb 5 zeigt den Erfassungsbereich des Bewegungsmelders Er kann wie in Abb 6 beschrieben mit den Einstellkn pfen und durch Neigen des Sensors Abdeckschraube l sen...

Page 4: ...ea of movement detector PIR as per Fig 5 You can select the scanning eld of PIR by adjusting the rotating adjuster and moving the PIR sensor as show in Fig 6 2 You can select the relay time from 15 5...

Page 5: ...mouvements 1 La figure 5 montre le secteur de capture du d tecteur de mouvements Tout comme ceci est d crit dans la figure 6 il peut tre modi au moyen des boutons de r glage et en orientant le capteu...

Page 6: ...l gebruiken of monteren 15 graden II Aanwijzingen bij de bewegingsmelder 1 Afbeelding 5 toont het detectiegebied van de bewegingsmelder Dit kan zoals beschreven op afbeelding 6 door middel van instel...

Page 7: ...liabile montare gli stessi in posizione orizzontale 15 II Istruzioni per il sensore di movimento 1 La g 5 rappresenta il campo di rilevamento del sensore di movimento Come illustrato nella g 6 questo...

Page 8: ...l se vizszintes helyzet ben 15 II A mozg s rz kel be ll t si utas t sa 1 Az 5 bra szeml lteti a mozg s rz kel hat t vols g t A hat t vols g a 6 bra szerint a be ll t si gombok s az rz kel elford t s v...

Page 9: ...pohybu 1 Obr zek 5 n m zn zor uje ak n hel hl si e pohybu Ak n hel hl si e pohybu m eme nastavit s pomoc regul tor nebo prost ednictv m zm ny hlu sklonu hl si e pohybu povolte rouby podle obr zku 6 2...

Page 10: ...romet v vodoraven polo aj 15 II Navodilo za nastavitev senzorja gibanja 1 Slika 5 ka e podro je delovanja senzorja gibanja Podro je se lahko tako kot je opisano v sliki 6 s pomo jo nastavitvenih gumgo...

Page 11: ...al 15 II Observaciones para el ajuste del detector de movimientos 1 La g 5 muestra el mbito de alcance del detector de movimientos Se puede modi car tal como se describe en la g 6 con los botones de a...

Page 12: ...detec o do detector de movimentos Esta pode ser alterada como indicado na g 6 com os bot es de ajuste e inclinando o sensor solte o parafuso de cobertura 2 A intensidade de ilumina o e o tempo de lig...

Page 13: ...tt st lla in r relsedetektorn 1 Bild 5 visar r relsedetektorns t ckningsomr de Det kan f r ndras s som beskrivs p bild 6 med hj lp av inst llningsknapparna och genom att luta sensorn skruva l s t cksk...

Page 14: ...14...

Page 15: ...s Vitre de protection Beschermglas Vetro di sicurezza V d veg Bezpe nostn sklo Varnostno steklo Vidrio de seguridad Vidro de protec o S kerhetsglas 5 1 Erfassungswinkel Detection angle Angle de detect...

Page 16: ...ugo Brennenstuhl GmbH Co 72074 T bingen Germany Kommanditgesellschaft Seestra e 1 3 Elektrotechnik Tel 07071 8801 0 Elektronik Fax 07071 87657 Sicherheitstechnik E Mail info brennenstuhl de 0102873 40...