background image

 20

PC3060 Price Computing Scale User Instructions

The scale must return to zero or a negative value before another sample can be stored.

Other products may be added by pressing the 

M+

 key. It may take up to 99 entries or 

until it reaches the maximum displayable digits.

To view the total price stored, press the 

M+ 

key when there is no weight on the scale. 

The total will be displayed for two seconds.

To clear the memory, press the 

CLEAR

 key, 

, to clear all values.

4.1.11 Give Change

After accumulating total price, you can use the 

CHANGE

 key to work out the exact 

change that needs to be given. (total being $24.60 in the example shown below)

1.

Press the 

CHANGE

 key, 

, and 

the 

Change

 annunciator in the 

TOTAL PRICE

 display will 

illuminate.

The total cost will now be 
shown in the 

WEIGHT

 

display.

2.

Use the numeric keys to enter in 
the money handed over by the 
customer ($30.00 in this 
example).

This will be shown in the 

UNIT PRICE

 display and 

the change will be shown in 
the total price display.

3.

Press the 

TARE

 key to return the scale to normal weighing mode and clear the 

account memory.

4.1.12 Commodities Without Weighing

For products that are not weighed but are priced individually per item, these can easily 
be added by using the 

QTY

 key.

1.

Use the numeric keys to enter the 
unit price of the item ($1.56 each 
in the example at right) and then 
press the 

QTY

 key.

2.

Enter the quantity (a quantity of 
5). The 

WEIGHT

 display will show 

5 and the 

TOTAL PRICE

 display 

will now show the total price 
($7.80).

Summary of Contents for PC3060

Page 1: ...PC3060 Price Computing Scale User Instructions AWT 35 501856 Issue AA...

Page 2: ...wo dimensional work and the making of a copy in two dimensions of a three dimensional work stored in any medium by electronic means or transmitted in any form or by any means including electronic mech...

Page 3: ...3 Introduction 12 Installation 12 Unpacking 12 Level Adjusting 12 Connect Adaptor 13 Parts description 14 Keyboard 14 Displays 15 Chapter 4 Operation 16 Initial startup 16 Power ON OFF 16 Zero 16 Tare...

Page 4: ...4 PC3060 Price Computing Scale User Instructions Replacement parts 27 Sealing 28...

Page 5: ...soft keys Displayed messages appear in bold italic type and reflect the case of the displayed message 1 1 2 Special messages Examples of special messages you will see in this manual are defined below...

Page 6: ...3 Electrical installation 1 3 1 Pluggable equipment Pluggable equipment must be installed near an easily accessible socket outlet DANGER RISK OF ELECTRICAL SHOCK NO USER SERVICEABLE PARTS REFER TO QU...

Page 7: ...s instructions ATTENTION Il y a danger d explosion s il y a remplacement incorrect de la batterie remplacer uniquement avec une batterie du m me type ou d un type quivalent recommand par le constructe...

Page 8: ...tly on to the display windows This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide...

Page 9: ...ng Units Kg lb Pan size 204 x 263mm 8 03 x 10 35inch Housing ABS Plastic and Stainless Steel pan Interface RS232 Output standard Operation Temperature 10 C 40 C 14 F 104 F Stabilisation Time 1 Seconds...

Page 10: ...10 PC3060 Price Computing Scale User Instructions 2 1 Dimensions...

Page 11: ...PC3060 Price Computing Scale User Instructions 11...

Page 12: ...on l Auto unit price clear operation l Weighing units conversion kg lb l Standard RS 232 ideal for connecting to a printer or a cash register 3 1 Installation 3 1 1 Unpacking Carefully take the scale...

Page 13: ...E LED on the front of the scale will show the status of the battery When the scale is plugged into the mains power the internal battery will automatically start charging If the LED is green this means...

Page 14: ...it price PLU In setting mode press numeric keys to enter parameters setting Clear incorrect entries and error conditions In fixed mode press to input double zero In float mode press to insert a decima...

Page 15: ...change units of weight unit price kg lb Quantity key use for entering in quantities without weighing Keys Press this key to BATT Battery indicator When illuminated battery requires recharging Plug in...

Page 16: ...isplay can easily be re zeroed by pressing the ZERO key 4 1 3 Tare When weighing produce on a tray film or container the weight of any container can easily be tared off so you only see the Net weight...

Page 17: ...hed on the weighing pan e g 1 5 lb 3 Enter in the unit price by pressing numeric keys In this example 5 00 is shown Key in 500 or 5 followed by a decimal This will now be displayed in the UNIT PRICE d...

Page 18: ...is shown Key in the desired stored PLU number 0 to 9 2 To recall PLU 1 press 1 Display will now load the stored unit price per the selected unit of measure 3 Place the item to be weighed on the weigh...

Page 19: ...ing unit from lb to kg The lb annunciator will go out and the kg annunciator will illuminate 4 1 10 Accumulation function The scale can be set to accumulate manually by pressing the M key To turn on t...

Page 20: ...the CHANGE key and the Change annunciator in the TOTAL PRICE display will illuminate The total cost will now be shown in the WEIGHT display 2 Use the numeric keys to enter in the money handed over by...

Page 21: ...PC3060 Price Computing Scale User Instructions 21 3 Press the QTY key to return normal weighing mode...

Page 22: ...ber to get into the parameter menu The display will show Pn 3 Press the TARE key to confirm The scale will now give you access to the parameter settings of the PC3060 and the display will show menu un...

Page 23: ...xternal resolution 6000 Dual i Dual r F2 CAP 3KG 6lb Set Scale Capacity 6KG 12lb 15KG 30lb 30kg 60lb F3 PdECi 0 Set Price Decimal Point 0 0 0 0 00 0 000 0 0000 F4 PdESC FIX Set unit Price to FIXED or...

Page 24: ...le Cont Continuous data transmission StC Stable data sending continues tole do Protocol Type 1 Toledo ncie cr Protocol Type 2 NCI ECR ncig en Protocol Type 3 NCI General tec Protocol Type 4 TEC easy P...

Page 25: ...pan and make sure STABLE indication is visible on the display 7 Press the TARE key to confirm unload is displayed 8 Press the TARE key to confirm CAP loadXX is displayed 9 If necessary press the M ke...

Page 26: ...of scales can be connected to a standard printer using the RS 232 output found under the scale 7 1 1 Print Format Total 300 00 Pay 310 00 Change 10 00 NET 10 000 Unit Price 30 00 kg Price 300 00 Total...

Page 27: ...5d Err 9 Unstable Reading Check any air variation vibration RF noise and touching somewhere Check the load cell and connectors Err 10 Communication error No data RS 232 continuous communication Err 15...

Page 28: ...Scale User Instructions 7 4 Sealing All sealing to be carried out in line with NTEP CC 18 119 or EC approval cert 0200 NAWI 05154 A wire seal is passed through the holes in two sealing screws mounted...

Page 29: ......

Page 30: ...37 0529 Tel 507 238 8702 Fax 507 238 8271 Email sales brecknellscales com http brecknellscales com Brecknell UK Foundry lane Smethwick West Midlands England B66 2LP Tel 44 0 8452 466717 Fax 44 0 8452...

Reviews: