5.1.2 Activating the Parameters
5.1.3 Parameter Menu Block
To access or change any parameter, the CAL switch located on bottom of the scale
may have to be pressed.
Press the CAL switch to enable parameters.
Menu
Sub-Menu
Description
F0 CAL
Calibration
F1 rES
3000
Set external resolution
6000
Dual-i
Dual-r
F2 CAP
3KG/6lb
Set Scale Capacity
6KG/12lb
15KG/30lb
30kg/60lb
F3 PdECi
0
Set Price Decimal Point
0
0.0
0.00
0.000
0.0000
F4 PdESC
FIX
Set unit Price to FIXED or FLOATING
FLOAT
F5 SPEED
Slow
To select A/D speed
Medium
Fast
F6 Min coin
1/2/5/10
Select minimum coin
F7 SCSIUE tare
ON
Multi - Tare function ON
OFF
Multi - Tare function OFF
F8 ISN
This display will show XXXXX for indicating the internal counts.
F9 Gra
To set your local gravity value.
F10 Reset
Factory default settings