PC3060 Price Computing Scale User Instructions
27
7.2 Error codes
7.3 Replacement parts
Error Message
Description
Solution
-----
Maximum load exceeded
Unload or reduce weight
Err 1
Incorrect date
Enter the date by using format “yy:mm:dd”
Err 2
Incorrect time
Enter the time by using format “hh:mm:ss”
Err 4
Zero setting error
Zero setting range exceeded due to switching
on. (4%max) Make sure platform is empty.
Err 5
Key board error
Check the keys and connecter.
Err 6
A/D value out of range
Make sure platform empty and check the pan is
installed proper. Check the load cell connectors.
Err 7
Percentage error
Value should be (0.01% weight must > 0.5d)
Err 9
Unstable Reading
Check any air variation, vibration, RF noise and
touching somewhere. Check the load cell and
connectors.
Err 10
Communication error
No data (RS-232, continuous communication)
Err 15
Enter gravity error
Gravity range (0.9~1.0)
Err 17
Tare out of range
Remove the load and restart scale again.
Err19
Initial zero error
Calibrate the scale.
--ol--
Over range
Remove the load. Recalibrate
Fai l h/ fail
Calibration Error
Recalibrate
Err p
Printer error
Check the printer and settings
Ba lo/ lo ba
Battery low
Recharge battery, check the voltages.
Part number
Description
AWT25-502479
Power supply USA (input 100-240V 50/60Hz 0.25A output 12V 0.5A)
AWT25-502480
Power supply UK (input 100-240V 50/60Hz 0.25A output 12V 0.5A)
Replacement battery
AWT20-509299
Replacement feet Kit (4 feet and lock nuts)
AWT20-509300
Replacement top pan
Summary of Contents for PC3060
Page 1: ...PC3060 Price Computing Scale User Instructions AWT 35 501856 Issue AA...
Page 4: ...4 PC3060 Price Computing Scale User Instructions Replacement parts 27 Sealing 28...
Page 10: ...10 PC3060 Price Computing Scale User Instructions 2 1 Dimensions...
Page 11: ...PC3060 Price Computing Scale User Instructions 11...
Page 29: ......