5.4 Time parameters
Parameter
Value
Meaning
Basic
51
q
Number of rings before the Brave picks up
(1-9)
2
q
– The number of rings before an incoming call is picked up. The Brave
picks up between rings 2 secs. after detecting the
q
-th ring. It is possible
to set the number of rings between 1 and 9.
Parameter
Value
Meaning
Basic
52
d
Maximum length of a call (0-9,*,#)
2
d
– The maximum length of time for which the Brave is
busy. It is possible to prolong this time during the
call by choosing a key (* or #) from the phone
(
parameter 42
). The setting of this time is in
accordance with the adjacent table.
Parameter
Value
Meaning
Basic
53
w
Time between button presses (1-
9)
2
w
– maximum time [in seconds] between button presses [range 1 - 9]
Normal buttons
-
Relay switch on
– if the time between presses is longer than time
w
,
then the code will not work correctly.
-
Choice of number
– if the pressed button is the first number of a
password to switch on a relay then the choice is delayed by time
w.
Keyboard
-
Switch on Relay
– if the time between presses is longer than the time
w
then the code will not work correctly.
-
Choosing of number
-
Choose from the phone, if the time after the last pressed button
is longer than time
w
, then the choice commences, if the number
is incomplete, it is necessary to disconnect (press the
X
key
)
and repeat the choice;
-
Choose from the memory, if the time after the last pressed button
is longer than the time
w
, then the choice needs to be repeated.
Time
[min]
Option
0,5
0
1 - 9
1 - 9
15
*
30
#