BRAVE Steel
–
User and service manual 43
Parameter
Value
Meaning
Basic
44
xxxx
Service password (0000-9999)
0000
xxxx
– service password to programme from a phone (DTMF)
If you forget the password, the following procedure is recommended:
1. Open the Brave front cover;
2.
Switch „DIP 1‟ to „ON‟;
3. Call the Brave;
4. Once the Brave picks up the system is in programming regime. In
this regime it is possible to change the password 44xxxx;
5.
Switch „DIP 1‟ to „OFF‟; and
6. Close the front cover.
Parameter
Value
Meaning
Basic
45
dd
Command for switch over to
DAY
(00-99,*0-*9)
11
46
nn
Command for switchover to
NIGHT
(0099,*0-*9)
10
Dd
command to switch over to the
DAY
regime [2 spaces] /
1
Nn
command to switch over to the
NIGHT
regime [2 spaces] /
1
/
1
command is always 2 digits, but if you wish to switch over from Day to
Night with a single digit from the phone, there is an option to input "
*a
",
where
a
is a single number and the star represents an empty space and
must be in the first place
(e.g. parameters 35,36)
Note.
The Day/Night switch over regime stays set following line disconnection.
Parameter
Value
Meaning
Basic
47
e
Regime system choice (0/1)
1
e
– Choice of regime numbers;
e=0
selects numbers from first and second
group,
e=1
selects numbers in accordance with the
Day/Night
regime.
WARNING !!
setting this parameter materially affects the number dialling!
Parameter
Value
Meaning
Basic
48
c
Keyboard connection (0-8)
0
c
–
c=0
connecting the NC-mod to the basic module only
c=1 - 8
keyboard connected to the first to eight place
WARNING !!
setting this parameter materially affects whole systems