Parameter
Value
Meaning
Basic
3*
r e
Exit button for relay r
(0/1/2)
10 20
r
– relay number [1-2]
e
– exit button regime:
e=0
- off,
e=1
– on for 1 impulse,
e=2
– on for 2
impulses
Parametr Value
Description
Default
3#0
p
p = 1 enabled / disabled p = 0 connection
code relay COSW (0/1)
0
p
– turns on transmission serial code to activate the first switch.
CAUTION
- at activation this function never connect to the circuit electric lock
without board COSW - code relay - threatens to destroy the relay in Brave
communicator!
The following codes may be the same or different for the resolution switching
on multiple parallel connected relay code.
Parametr Value
Description
Default
3#1
abcd
activation code 1 pulse from buttons
(0000-1111)
0000
abcd
–
Brave sends a serial code for the code relay (COSW) after
evaluation code from keys (keyboard) namely for 1 pulse
Parametr Value
Description
Default
3#2
abcd
activation code 1 pulse from phone
(0000-1111)
0000
abcd
–
Brave sends a serial code for the code relay (COSW) after
evaluation code from telephone (DTMF) namely for 1 pulse
Parametr Value
Description
Default
3#3
abcd
activation code 2 pulses from buttons
(0000-1111)
0000
abcd
–
Brave sends a serial code for the code relay (COSW) after
evaluation code from keys (keyboard) namely for 2 pulses